I checked the heat flux at R=0 in my model, it was not equal to zero although I have assigned heat flux to zero in a function defined in "Fields"-"Analytical fields". I don't know where might go wrong to cause the inconsistent input/output.
Shall I try to add additional constrains, say tie the...
Thanks Corus.
I apply frictional heat source in the format of a mathematical function throughout the radius at the inner surface including R=0. The function gives zero heat when R=0. This model is not hollow. I modeled a pin and plate friction test rig. I built all parts in one model and...
Hello, Colleagues.