  1. nitin36537

    Punching shear % steel

    Hi Thanks Kootk On second thought , I too agree with your suggestion. Few more doubts. Why compression steel is not contributing to punching shear strength ? For my case , Ast1 & Ast2 are almost same area. Why BS 8110 is considering critical section for punching at a distance of 1.5 * d ...
  2. nitin36537

    Punching shear % steel

    Dear All We are designing a foundation having two RCC slab as per BS 8110. Three layer of rebars provided. Refer attached PDF file As per BS 8110 , for calculating punching shear capacity we have to consider % tensile reinforcement. Critical section for punching shear is at a distance of...
  3. nitin36537

    Insulation coordination

    Thanks Transmissiontowers We follow Indian code IS-5613 for lines in our country. We are doing lot of works for other countries also where we follow EN , NESC etc. Most of the time client specify required distance. As per my observation it is same as live metal clearance required under no...
  4. nitin36537

    meaning of section length

    It is horizontal span length.
  5. nitin36537

    IEC 60071

    In IEC 60071 ,why there are multiple values for one system voltage. For example for 220 Line. System highest voltage = 245 KV Short duration power frequency withstand voltage 360,395,460 Lightening withstand impulse voltage 850,950,1050. May be silly question , As I am Civil engineer. Thanks...
  6. nitin36537

    meaning of section length

    Section length is sum of spans between angle towers (Tension Towers). I am not sure about how it is related with wind loading. Nitin
  7. nitin36537

    Insulation coordination

    How to calculate required distance between arcing horn on insulator (Line side to tower side) of 220 KV transmission line for line having altitude of 1500 m to 2000 m above mean sea level. Does this distance depend on elevation of line ? Does it depend on rated impulse withstand voltage of...
  8. nitin36537

    Insulation coordination

    How to calculate required distance between arcing horn on insulator (Line side to tower side) of 220 KV transmission line for line having altitude of 1500 m to 2000 m above mean sea level. Does this distance depend on elevation of line ? Does it depend on rated impulse withstand voltage of...
  9. nitin36537

    Sag tension calculation , referance

    How can we develop ( Manual / Excel sheet ) sag tension calculation of conductor considering creep effect ? We are doing this using PLS Cadd . Is there any books / reference material so that we can match the result of PlsCADD in excel / Manual calculation ? Thanks Nitin Patel
  10. nitin36537

    Optimized cutting of steel angles using EXCEL

    1-MT stand for metric ton 2-100*100*7 is steel angle section ( L shape )with both flange having 100mm width and 7mm thickness. 3-Minimizing wastage is main criteria.If we minimize wastage balanced material can be used for other project. 4- ??? 5- YES [wink] Regard
  11. nitin36537

    Optimized cutting of steel angles using EXCEL

    Dear all During cutting if remaining Pieces length is less then 500 mm then it is a wastage. If it is more than 500 mm then we can consider that same pieces will be utilized for other project.So minimum wastage is the goal. Also please note that cost is define as $/MT. Excel file is...
  12. nitin36537

    Optimized cutting of steel angles using EXCEL

    Can you please provide steps/methods ( Reading materials) required to find out solution. preferably with EXCEL/ EXCEL VBA Regards Nitin
  13. nitin36537

    Number of holes in Double angular

    1 - You should not ( Can not ) count splice plate and splice angle area for net area calculation. 2 - No of holes for deduction minimum Four ( In case of no zig zak failure). For design consider Six to Seven in PLS. 3 - 103% ( With out considering splice plate & angle )is OK as in real...
  14. nitin36537

    Optimized cutting of steel angles using EXCEL

    Can someone suggest how to determine optimum cutting schedule from a give stocks of angle sections using excel? Stock data 100*100*7 ---- 5000 mm 150 qty cost 1000 $/MT 100*100*7 ---- 6500 mm 25 qty cost 1050 $/MT 90*90*6 --- 6500 mm 100 qty cost 1020 $/MT 90*90*6 ---- 5500...
  15. nitin36537

    Redundant member in lattice towers

    For heavy tower many a times redundant design is govern by % of leg load. We have to design redundant for 1.5 to 2.5 % of leg load. Nitin
  16. nitin36537

    KL/r Ratio for staggered bracing

    This is 500KV S/C tower. Loadings are as per IEC. Tower is square base. we are using PLS Tower for analysis. During testing some redundant members are added ( Refer attached line diagram ). Tower is successfully tested with added redundant members. My point is , Even if ASCE 10-97 clause is for...
  17. nitin36537

    KL/r Ratio for staggered bracing

    P7 is corner leg , P7T is lattice member of transverse face and P7L is lattice member of longitudinal face. P7 is supported from both face. ( Not staggered ). Member P7T and P7L are not supported from two side at every point. We face problem during tower testing with this pattern during...
  18. nitin36537

    KL/r Ratio for staggered bracing

    AS per ASCE 10-97 while calculating l/r for leg member which is continuously staggered as shown in fig 3.2 b and 3.2 c of ASCE 10-97 , we have to consider kl/r = 1.2 l/r. Does this apply only to leg members or it will be applicable to lattice member also. (Lattice p7T as shown in attachement) ...
  19. nitin36537

    Loading tests on overhead line structures

    Whatever wind load values you calculate ( Manually or Through PLS ), before testing do PLS Tower analysis with wind load as point load on model and make sure that all members are OK. Do not forgot to distribute wind load on top and bottom nodes. Nitin Patel
  20. nitin36537

    Deadman anchor of Guy tower

    For one of the project we need to design dead man anchor block foundation for guy anchor. Maximum tension is 270 KN in guy wire. We have to design for 405 KN tension. Guy slope with horizontal plane is 54 Degree. After deciding shape of dead man anchor(3.5m * 0.45m * 0.45 m )and Foundation...