Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. leostar81457

    Velocity limit for Flow Induced Vibration

    Yes GDD and LittleInch, these pipes are part of the upstream oil and gas facility. These are condensate pipelines connecting to the main header, then goes to the Separator Vessel. I am looking to evaluate the main headers first; the Inlet header to the vessel, and outlet gas header. Currently...
  2. leostar81457

    Velocity limit for Flow Induced Vibration

    Apologies for the misunderstanding. "It is really critical considering the business management want an immediate response" - I wrote this not to force anything out of anyone. Just wanted to share what most workers have to deal with every time regarding the business side, and which most of us...
  3. leostar81457

    Velocity limit for Flow Induced Vibration

    Dear All, Thank you all for your reply. It is really critical considering the business management want an immediate response. Thank you all for the references that you shared, I will look in to it. For the slug flow, the confirmation was taken from the process team to rule out the slug flow...
  4. leostar81457

    Velocity limit for Flow Induced Vibration

    Hello All, Can anyone share any experience or reference on what is the maximum velocity that is allowed in a piping, mostly in terms of Flow induced Vibration? I am expecting static analysis will not be affected by the increased velocity, only the dynamic needs to be considered (FIV). This is...