    Coal Fired Power plant Pulverizer CD is consuming more power

    Each Mill has their own Gravimetric feeder where the weight measurement done. We done all the measurements. There are two units of 250 MW. both have the same problem.. Is it possible that PA is taking the least resistance path to Mill AB and EF? Is it possible to create artificial resistance...
  2. icecool

    Coal Fired Power plant Pulverizer CD is consuming more power

    Dear All, I am working in a 250MW Coal power plant. This power plant has 3 Tube mills. normally 2 are in service. These mills named as AB, CD, and EF. The problem is whenever I take Mill CD in service. It consumes more power than other mills (Mill rating is 2350 kw, Mill AB and EF takes around...
  3. icecool

    Steam Turbine performance with variation in inlet steam pressure

    hermit47, What is component number? Does it relates to number of stages in a turbine. Also it seems to me that the pressure lines are parallel to each other in most part of the expansion. That means apart from low pressure region the expansion at different pressure will be same?
  4. icecool

    Steam Turbine performance with variation in inlet steam pressure

    hermit47, Please see the attached HMBD for 60MW case. http://files.engineering.com/getfile.aspx?folder=42609aea-5154-4ddb-a254-19776005f0a2&file=60mw.png
  5. icecool

    Steam Turbine performance with variation in inlet steam pressure

    The turbine of condensing type. It is connected with ACC. It is designed for .18 bara pressure at 60MW output.
  6. icecool

    Steam Turbine performance with variation in inlet steam pressure

    Hermit47, The HP turbine exhaust is connected to moisture separator which is connected to reheater. After reheating the steam enters inside the LP Turbine. HP Heater 1 extraction is at 36 bar, 256 degree C, and flow is 5.2 kg/s. The Deaerator and other HP heater take extraction from the HPT...
  7. icecool

    Steam Turbine performance with variation in inlet steam pressure

    Thanks hermit47 Few more questions: 1. I know the turbine upstream pressure. But will the HP Turbine downstream pressure will remain same ( I mean the HPT exhaust pressure is 23 bar when the HPT inlet pressure was 98 bar. Now what happens when the inlet pressure goes down to 75 bar? I know...
  8. icecool

    Steam Turbine performance with variation in inlet steam pressure

    hermit47, Could you please tell me more about the Turbine constant. I am not aware of it. Also how did you come to a number 221.8 kg/s and 39.5 MW? as I mention it is a HP-LP combination turbine. The total mass flow rate at the inlet of the turbine is 70 kg/s. racookpe1978 Could you please...
  9. icecool

    Steam Turbine performance with variation in inlet steam pressure

    hermit47,Turbine will produce less power. are you sure? because my temperature remains same.Therefore actually the inlet enthalpy will increase little bit. Theoretically the power output might be same? But what about the kinetic energy turbine needed for driving force. As I understand the...
  10. icecool

    Steam Turbine performance with variation in inlet steam pressure

    Dear All, I am estimating a future problem while still in erection phase for 60 MW steam turbine. I may need your help to estimate a solution. Due to some reason my process heater is not able to generate steam at the desired pressure (other parameters are remain same). Therefore I want to...
  11. icecool

    VFD application on Pump

    Thanks all for your valuable input.
  12. icecool

    VFD application on Pump

    Its a coincidence that both are 900kW. But they are different. Thanks BigInch, Yes you are correct. There are 2 streams Stream 1: Heat Transfer Fluid : HTF Pumps it through solar field, get some heat, and then passes through the Steam Generator and transfer energy to Water/Steam Stream 2...
  13. icecool

    VFD application on Pump

    Artisi, You are combining 2 different posts.. This VFD is for Boiler Feed Pump while the other pump was HTF (High Temp Fluid) pump..So both are independent and flowing different liquid in different circuit.
  14. icecool

    VFD application on Pump

    The Pressure in Steam Generator is 110 bar(a) Its 3000 RPM (please see the 1st post Frequency is mention as 50Hz). Does it matter whether its 50Hz or 60Hz frequency? The pump flow rate is 150 m3/hr. it's a BB5 pump. Let me know if any more details needed.
  15. icecool

    VFD application on Pump

    Hello Everyone, Can anybody suggest me whether it is useful of adding VFD in Boiler feed pump in a power plant. I gone through the details. I understand the advantages of VFD but not sure about the overall burden of VFD on O&M cost. The overall cost of VFD is almost equal to the cost of Motor...
  16. icecool

    Whether A Pump with Gear Box (to increase pump speed) is Feasible?

    Dear LittleInch, I do. Thanks everyone. I have theoretical answer of the questions. But I am still not sure from O&M easiness. Also, I found a supplier who can support me on this. Thanks, Lokesh
  17. icecool

    Whether A Pump with Gear Box (to increase pump speed) is Feasible?

    Dear LittleInch Basically this is a solar thermal power plant. The high temperature oil is goes through the solar field and collect heat and back to steam generator and transfer energy to water. The high TDH value is mainly due to plant size and low efficiency of solar. It is a confirmed...
  18. icecool

    Whether A Pump with Gear Box (to increase pump speed) is Feasible?

    Dear desertfox, Can you please elaborate "reduction in output torque after the gearbox and also whether the motor will cope with the increased inertia load of the gearbox". Thanks
  19. icecool

    Whether A Pump with Gear Box (to increase pump speed) is Feasible?

    No..its typing mistake..it is 1100 m3/hr.
  20. icecool

    Whether A Pump with Gear Box (to increase pump speed) is Feasible?

    What power is your existing motor or are you changing that also? : approximately 900kW Have you considered a bigger impellor in the same casing? I already tried bigger impeller in the same casing but it won't fit. Your flow will Increase in proportion, but head increase as squared (+44%) and...