Hai all, I operate Gas Turbine with power output 186 MVA, 16 stages compressor and 4 stages turbine. Because off network request the gas turbine often start and stop in same day. When gas turbine shutdown, it will brought to turning gear operation at speed about 90 rpm for 24 hours and then turn...
If I can take the conclusion, that the type of gas compressor with oil injected screw will allow the oil to absorb water and hydrocarbon gases contained within. If these conditions continue to occur, it will cause loss of quality gas compressor oil. There are several possible solution that is...
Oil used in accordance with manufacturer's recommendations screw gas compressor, KOBELCO, KB-105-68.
After 7200 hours of operation the viscosity dropped from 68 to 41 Cst and followed with oil color changes to white milk.
There is one odd thing about the gas separator upstream side of the...
Unfortunately deluge valve to regulate the flow of oil to the cooler to be set at 50 C.
Gas compressor only 1 unit available as a gas booster to the gas turbine.
Thanks to zdas04 to answer pretty clear.
I also did a test to degas the sample gas oil compressor oil which can be recovered visual along with my sample viscosity when heated at temperatures of 160 C. If this show is so great that damage portion of C6+ gas compressor oil?
Indeed, there is an...
Hello, I am new in the Eng-Tips forums and my background is not sufficient to determine the cause of the problems regarding the Oil Flooded Screw Compressor that I was dealing with.
I found conditions in the screw compressor oil in milk white condition after operation for 7200 hours. Conditions...