Calibration to the Master was done 2 months ago, I have also conducted tests off the Master that was Calibrated by the Fluke Corperation in January with the same result.
Yep, Ive talked to several people over there and they have agreed with me that something is wrong, but no one has proposed any solution to the problem or reason yet after two weeks.
I work in the Forging industry and I am having an issue where Raytek 3i series Model 2ML3 IR guns are consistantly giving low temperature readings (such as 975 F when the actual temperature is 1200F) accross all grades and temperature ranges. [The actual temperature is measured by a surface...