Hi, thanks for the response! Yup, I've reviewed it, but keeping that in mind, for the -33 deg C (-27 deg F or so) application I feel that the minimum impact energy requirements would be too conservative.
Is there any master curve or extrapolative approach that can be used for CVN values NOT at...
Hi guys, this is my first post here.
I'm working on a critical flaw sizing job of a pressure vessel which has A333 Gr.1 nozzles under a low temperature condition (-33 Celsius).
The client is unable to provide us with fracture toughness or Charpy test data.
As such I was using API-579 Annex...