Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. frank201

    Pipeline cathodic over protected

    for sacricficial anode it's difficult to measure the E OFF , i think is better to use corrosion coupon to mesure the E off
  2. frank201

    Pipeline cathodic over protected

    each 25 anode are branched together in one test point
  3. frank201

    Pipeline cathodic over protected

    Cu/CuSO4 reference electrode The number Mg anodes is 100 anodes (7kg) spacing approximately 30 metres thanks
  4. frank201

    Pipeline cathodic over protected

    Dear expert . We work in new construction (12 inch) pipeline 3 km with 3LPE coating. The method we are used in cathodic protection is Sacrificial anode. We make 4 Test points . The potential (CSE) is around -1600 mv ( pipe over protected) Please advise if there some risk of coating disbanding...
Back
Top