Thank you all for the responses. I should have already thought about using excel, I have it on my phone. I will also look into the Smath app. It looks like a good program. Thank you again.
My old TI-86 programmable calculator from college (mid-90's) has finally bit the dust. I had written several simple programs in the calculator that let me solve an equation by inputting values for variables. They were simple programs that did things like ask me for a temperature, pressure, and...
Does anyone have any experience with minimizing the impact that piping x-rays have on nuclear point-source level detectors. Are there any practices, (besides placing controllers in manual), that are successful with minimizing upsets to the readings?
The best thing you could do would be to have one of your Elect/Instrumentation Technicians go out and actually read the pumps instantaneous amp draw. At the same time have pressure gauges installed on the pump suction and discharge and also record the pumps discharge flowrate, (if the pump has...
At my facility we offload 45% KOH from a railcar. The 45% KOH is pumped from the railcar into a mixing tee where it is diluted to 20% wt with water. A setpoint is entered for the KOH flow, and the water flow is ratio controlled to supply the correct dilution ratio. Just downstream of the...
Mucour, I think this was an interesting question posed, but I think its more academic/theoretical than practical. If you work in an industrial situation where you have a reasonable potential for a cent. compressor to run blocked in; or some other part of the process has a reasonable potential...
1. Spin your fans faster. Bigger motor with a VFD which controls column pressure.
2. I think I read something once about someone that temporarily reverses the fan direction on some frequency to blow dirt off the outside of tubes (for induced draft fans).
3. You can hire a chemical cleaning...
A Working Guide To Process Equipment and Troubleshooting Process Operations, both by Norm Lieberman. Best books I ever read on Process Engineering. I don't think I was ever really a Process Engineer until I read them. Also suggest Perry's, Crane, Cameron's, and anything by Nicholas Chopey and...
Make very sure that you size the check correctly if you go with a piston check. Make very certain there is zero potential for solids in the process line containing the check, and most of all make sure there is enough momentum in the line you are checking to ensure it remains fully open. There...
Based on your description I would say that the Column you are looking at is a thermosyphon with a partition wall in the sump. The liquid from the bottom tray, or packing, is funneled to one side of the column. It falls down into the "reboiler" sump which is separated from the main sump by a...
Isn't there some use you can find for this energy rather than just throwing it away?
At today's gas prices, for every 10,000 LB/HR condensate that you are letting drop from 75 to 3 psig, you are sending $5/hr out into the atmosphere.
Enthalpy of 75psig sat liquid = 291 Btu/lb
Enthalpy of 3psig...
I wish I could help you more sshep, but I have never operated, seen, or even read about a vapor side draw. Certainly not saying they don't exist, I just don't know anything about them. It kind of seems like if you have a point in the tower where your vapor is meeting the spec you are looking...
Thank you all for the postings. I certainly like the thought of a mass meter as ASHERENG describes, however we just don't have enough room to put one in the suction of the pump. The suction piping is very short and any re-piping or addition of length would only add to the settling problems we...
Thank you JMW. The main reason for the PD pump is due to the need for a high discharge pressure (> 1000 psi). I'm interested in your density meter suggestion. I don't think air entrainment or solids deposition would be a problem with this application. How accurate would the meter be? Would...
I have a problem that I was hoping someone might have some experience with or could offer some tips/advice on. I am looking for a way to measure online a slurry concentration in a vessel.
The operation involves a small vessel, (3.5'-I.D., 4'-Tan/Tan, approximately 330 gal.), in which we mix...
Such a work does exist. The best part is the best one out there is free and on the web. The book is called "Ethylene Oxide". It is made available through a collaboration of the major industry producers of EO. Just type "www.ethyleneoxide.com" and there you are. If you are going to be...
You could look into renting a stainless truck trailer. I've used one before to feed acid into my Unit for a short duration temporary facility. I'm giving out this option with the assumption that a thorough MOC would be done and followed. You would have to think in detail about containment...
James1030Bruce, you need to go through the tower and inspect it. This is one of the most important jobs process engineers do. Study all of the drawings very closely so that you understand exactly what you are looking for in each section of the tower. Make a cutout like sshep recommends and...