Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. kixter

    Basis for 0.2L Saddle Location

    codeeng: thanks for the quick response. As I anticipated, it is only a rule of thumb and provides some guidance to help reduce the chance of exceeding allowable stresses. I will keep a close eye on all the stresses produced. Thanks again! JC
  2. kixter

    Basis for 0.2L Saddle Location

    Does anybody know what is the basis for limiting the distance between a head tangent line and the center of a saddle to a maximum of 20% of a vessels length? I have read through Zicks paper, Bednar, Megyesy, Harvey and (I think) all likely threads here, and can find no specific engineering basis...
  3. kixter

    Air Reciever Corrosion Allowance

    To all- Thanks for the input! Lots of good practical advice here. I recognize the real world need for providing a corrosion allowance in air receivers, hence my questioning a corrosion allowance of “0” for a pressure vessel sold as an air receiver. It would seem that the manufacturer should...
  4. kixter

    Air Reciever Corrosion Allowance

    What are the requirements for corrosion allowance in ASME Section VIII, Division 1 air receivers? Non-mandatory Appendix E requires it to be considered by the designer. The codebook index refers to UCS-25 which has been deleted from the codebooks for sometime. The question was raised when...
Back