Thanks a million for your response.
Actually,the end type of valve is VIAR LOCK hub type with clamps,and valve body is 3 pieces(2 hub ends + 1 body). In this case,two more question need your help
1)Is A-182 F316/316L suitable for materials of clamp?should be 60K minimum or not;
2)Hence they...
What is the work scope of technical manager? Take in charge all designers, arrange design works, or review plan & DOCs?
Are there corresponding study courses or books?
Thanks
Sean
Can ASTM A-182 F316/316L material be used for ball valve body which follows API 6A standard and 10,000psi rating ?
API 6A table-7 shows body material designations for pressure rating 69.0MPa(10,000psi) is 36K,60K,75K,NS while the yield strength of ASTM A-182 F316/316L is 205 MPa(30K). So this...
By the way,is my understand right for the PWHT exemptions for P-No. 1 material in table 331.1.3
a)thickness>25mm:preheat of 25℃ + multiple layer welds
b)thickness 5~25mm:multiple layer welds
c)thickness ≤5mm:not mentioned in the standard