Dear danw2, thanks for reply, we are not fishing actually we have selected flow meter against attached provided operating conditions.
http://files.engineering.com/getfile.aspx?folder=b92f3218-9053-4fa0-b584-c7bf24071799&file=Operating_Conditions.jpg
and not neglected to reveal on CR4 as stated...
Greeting,
We have installed Prowirl F200 DN80 on Saturated Steam, against following operating condition which was given by client.
Flow: 8000lbs/h , Pressure: 10 bar , Temperature: 170C, Line Size 6 inch
Applicator display the following outputs for these conditions
Meter Size: DN80
Velocity 41...