  1. MJFellow

    Information required

    Thanks, Good reason, but confusing and stupid, no other text book refers like this.
  2. MJFellow

    Information required

    Rb1957, Everyone knows H and V are the Horizontal (H) and Vertical (V)components, the question is why do you need to add the zero (0)value.
  3. MJFellow

    Information required

    Does anyone know, In Bolt Group Analysis Page D1.14 Bruhn, why there is a value Zero added to the Componenet Bolt (C) load equations. Sum H = 250 + 120x1/1.25 + 0 = 346 lb Sum V = 250 + 120x.75/1.25 + 0 = -122 lb Is this a mistake print error or does it mean anything ?
  4. MJFellow

    Polyurethane/rubber coated transport roll design question

    Hello Nick, I wonder whether you could help me. I have a silicon rubber seal for a window, A-A-59588A ASTM D412, where I can only find the tensile strength test allowable in Table 1 of the spec. Can I knock down by 60% to get the shear allowable. You comment appreciated PS: Where can I...
  5. MJFellow

    Insert Pull Out

    Thank you for the very useful information.
  6. MJFellow

    Insert Pull Out

    Hi Guys Does anyone know where I can get the data sheets to find the Insert Pullout strength through the Honeycomb panel with composite facing skins, ESA document is currently under review. Thanks in advance
  7. MJFellow

    Where can I find this..

    Thank you fellow Stressers, you have confirmed my doubt, now I can go back to the organisation who submitted the report. Sorry the link is for the smile, and didn't work
  8. MJFellow

    Where can I find this..

    A report refers to: From classical laminate analysis theory Fs=3M/2Rbt where M is the applied bending moment R is radius of curvature b is plate width t is plate thickness Can someone help me to find the source of the equation.
  9. MJFellow

    Information required

    Could anyone please let me know, if you have any techincal information: I have a window manufactured from Acrylic (MIL-P-5425) mounted to door frame manufactured from composite (7 layers of Carbon Fibre 199-45-005, Type A, Style 5H),) by using rubber seal (A-A-59588A Class 1A), 55 knots gust...
  10. MJFellow

    Structural Repair

    Referring to Manufacture's Description Hysol EA 934NA is a two-component thixotropic paste adhesive, which cures at room temperature and possesses superior strength to 300°F/149°C and higher. Its thixotropic nature and good compressive strength make it ideal for potting, filling and fairing, as...
Back