  1. hianbotech

    Discrepancies Between Api 521 Add 2008 And Jan 2014 For Unwetted vessels in fire case

    The file that you checked only shown the changes in the latest revision. The API STD 521 fifth edition, January 2007 (includes errata June 2007), addendum May 2008 has 206 pages. This is the standard that I checked. The new API STD 521 is the 6th edition,January 2014.
  2. hianbotech

    Discrepancies Between Api 521 Add 2008 And Jan 2014 For Unwetted vessels in fire case

    see section 5.15.2.2.2 Vessels containing only gases, vapours or super-critical fluids, pag 42 F' can be determined using equation (9). If calculated using equation (9) and the result is less than 0.01, then use a recommended minimum value of F' = 0.01
  3. hianbotech

    Discrepancies Between Api 521 Add 2008 And Jan 2014 For Unwetted vessels in fire case

    I found big discrepancies between our relief valve sizing and the vendor sizing for fire scenario in unwetted vessels when F' is less than 0.01. The discrepancies are based in the version of the API 521 used for the calculation. Our calculation were finalized last year and based in API Std 521...
  4. hianbotech

    Temperature of upstream piping. Blowdown utility HYSYS

    The temperature to be checked is: the minimum inner wall temperature. That's the temperature that the vessel/pipe will reach during the blowdown. To get the right inner wall temperature you must be carefull in hysys with the following information: * the weight and material of the vessel and...
  5. hianbotech

    Tethraetylene glycol gas dehydration units

    Suppliers for dehydration systme with TEG NATCO PROSERNAT FRAMES
  6. hianbotech

    vapor recovery in tanks

    Thanks to all for your answers: Our Client finally decided: 1. kept the floating roof tank. These tanks have an internal floting roof. 2. Seal the fixed roof portion of the tanks and pipe the vapor from the tank to a vapor combustion system. 3. Added a refrigeration system to reduce the...
  7. hianbotech

    vapor recovery in tanks

    IFRS thanks for your answer. Which did EPA regulations mention that pressure limit?
  8. hianbotech

    vapor recovery in tanks

    This flow came from the maximum filling rate that you can have in terminal, filling two tanks at the same time. Currently this flow was change for the client to 0.34 MMSCFHr. Regarding with the type of tanks. I have found several technical information that not recomended floating roof tanks for...
  9. hianbotech

    vapor recovery in tanks

    I am working in feasibility study. We want to change the service of two existing tanks in a storage terminal. The new product to be handled in the existing tanks will be condensate (light naphta), with a maximum RVP of 15. The current tanks are floating roof. For the new service these ones...
  10. hianbotech

    Heat losses in a tank

    Finally, as Montemayor said, we will need an air fan cooler in order to get the maximum temperature of 50°C at the outlet. However we would like to check how many degrees could be reduced in the system (tank and outlet pipe) without air fan cooler. In the pipe we know how calculated the...
  11. hianbotech

    Heat losses in a tank

    We also think that it is difficult that the temperature will be reduced until 50°C. However we would like to know how many degrees could be reduced. The personal protection insulation that we will be installed is metal shields instead insulation, the we will improve our heat loss. Our...
  12. hianbotech

    Heat losses in a oil tank

    I did not complete the post. The question is: How can I calculate the temperature in the bottom of the tank?. Best Regards, Hianbo
  13. hianbotech

    Heat losses in a tank

    I did not completed the post. The question is: How can I calculate the temperature in the bottom of the tank?. Best Regards, Hianbo
  14. hianbotech

    Heat losses in a tank

    We have this problem. We are designing a tank that will receive 2200 BPD of foamy oil at 80°C. The inlet nozzle will be located at the top of the tank. Inside of the tank the normal liquid level is 5 feet. This equipment is not insulated; only personal protection insulation is needed, because it...
  15. hianbotech

    Heat losses in a oil tank

    We have this problem. We are designing a tank that will receive 2200 BPD of foamy oil at 80°C. The inlet nozzle will be located at the top of the tank. Inside of the tank the normal liquid level is 5 feet. This equipment is not insulated; only personal protection insulation is needed, because...
  16. hianbotech

    Sample quill in small diameter pipes

    We are designing a sample connection to be installed in a 2" produced water line. this lines operate in a intermitent service. Is it possible to install this sample connection without a sample quill?. Pipig group has problems with the installation of quill in small diameter lines. The other...
  17. hianbotech

    NG pressure relief stack

    The most recommended type of vent stacks are vertical design. Additionally it is the most recomended from safety point of view. If you want a specific design criteria for design the vent see API 521 "Guide for pressure-releiving and depresurization system". A radiation and dispersion study...
  18. hianbotech

    Relief Valve (Fire Case) for amine - LPG tower

    Montemayor: The tower operates with MDEA (55% water) and LPG, liquid - Liquid contactor, at 420 psig and temperatures between 125 and 148°F. The amine is used to remove the H2S in the LPG In the first estimated when I calculated the possible relief load for pool fire scenario. I get that the...
  19. hianbotech

    Relief Valve (Fire Case) for amine - LPG tower

    Where could I find guidelines to design a relief valve (fire case) for a amine-lpg tower (liquid-liquid contactor tower). I know that the relief valve will open in fire case when there will be vapor in the top. However the relief valve will handle liquid-vapor mix. How can i estimated the...
  20. hianbotech

    Safe distance from fired heaters

    You need a Quantitative Risk Analysis in order to know all credible scenaries in your plant. The Quantitative Risk Analysis consists in a systematical evaluation of the facilities, in order to identify any potentially dangerous event and to estimate the damages to exisiting facilities and...