We have provided filters to a customer. The customer is questioning the design of the filters and whether it is suited to the application.
the filters were supplied by one of our vendors.
The questions has to do with how the filter bowl attaches to the housing.
The vendor said that it is a...
Thanks for all of the responses.
We are using the stainless steel because of the customers preference. Mostly aesthetics I think. At their European facility they used "plastic" pipe for the CA system and had problems with it.
As it turns out the other services in the rack require more support...
Thanks Montemayor, I should have mentioned stainless, 3" to be exact and we are using it for a compressed air system.
We will be sharing a pipe rack with other services (pneumatic conveying and cooling water) in an injection moulding facility. Considering the other service, we are not likely to...
I did a quick search for support spacing recommendations and find plenty for sch 40 and up but not Sch 10.
Does anyone know of a reference for this info?
Thanks
Scott Layman
Does anyone know where I can find information for pipe joints P-3 and up? I've got S9074-AR......278 but am lackikng in other references.
I am designing a header for a compressed air dryer and need to determine what type of welded joint connection is ok between my 3" Sch 80 SS header and the...