    Welding HDPE pipe and pressure drop

    Some older literature on HDPE used t say that the bead causes the pipe C value to drop to 140 from 150 but it is common tday to have the bead removed after installation to keep the flow at 150. Plasguy
  2. plasguy

    Buried Thermoplastic Pipe Celerity-Effect of Embedment

    Hello, ys thus topic has been studied extensively by the PVC pipe industry and educational institutions such as Utah State Univ. Your best best is to buy a copy of the PVC Pipe Handbook from the Uni-Bell PVC Pipe Asociation in Dallas, TX. It can be ordered thru www.uni-bell.org. You will find...
  3. plasguy

    Negative pressure C-900 CL150 sewer forcemain

    The negtive pressure of 16 ft will be absolutely no problem wit 8" C900 PVC. Both structurally due to high collapse strength and for the gasketed joints which are tested to 25 ft negative pressure as part of ASTM and CSA standards. For more info., contact IPEX at www.ipexinc.com
  4. plasguy

    Forcemain Cost estimates

    Uni-Bell PVC Pipe Association has a brief manual called Forcemain Design using PVC pipe, and they also sell a Handbook of PVC PIpe, very informative. Also could contact IPEX in Canada or US who provide tech, info. on PVC and other plastics (www.ipexinc.com). Plasguy
  5. plasguy

    24"/30" Water Transmission Main

    I think you will be much further ahead with PVC due to longevityhere are a variety of pressure ratings available as per AWWA C905 going from 80 psi to 165 psi for those sizes. All design information canbe found in AWWA design Manual M23 for PVC pipe. PVC fabricated fittings (similar to steel)...