Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. rcvonbrecht

    Turbine Meter without Flow Straightener

    The installation of gas turbine meters is more govern by AGA Report 7 and they take a little differnet bent. They're not perscriptive as API so vendors have different recommendations for turbine meters. For smaller meter you could use a confirguraion like that shown in the attachment...
  2. rcvonbrecht

    Naptha High temp. pressure measurement technic

    Man 500°C really puts you out there. Are you sure about that spec? Hydrocarbons tend to coke at these temperatures. This is the reason that you can't find reliable fills above 300°C they break down and release vapor which is death to pressure measurement. The gas law takes over at that point...
  3. rcvonbrecht

    Turbine Meter without Flow Straightener

    The amount of straight run is a function of what is happening prior to the run. If you have a couple of elbows then you have trouble. You’ll get swirl which is a flow vector that is not orthogonal to the pipe axis. This will reduce your accuracy. API MPMS 5.3 allows 5D upstream for a standard...
Back
Top