  1. puigi

    Pressure Vessels Reliefs or System Design Proctection

    I don't believe the exceptions in non-mandatory appendix M apply to the configuration you describe. Before you go down this path I recommend you read paragraphs UG-125 & UG-140 of ASME section VIII. UG-125 states that all PV regardless of size under the scope of the division shall have...
  2. puigi

    PSV Service Tags

    Read 2011 NBIC Part 3 (Repairs and Alterations), Section 5 Para. 5.12 Stamping Requirements for Pressure Relief Valves.
  3. puigi

    Choosing a boiler for use in acidic environments

    I recommend your consider a condensing boiler, they can achieve high efficiencies. These units operate with the flue gas below the acid dew point, corrosion resistant materials are used throughout the combustion and exhaust sections.
  4. puigi

    Basic Question Looking for member experiences

    Using RO/DI water as your feed-water source should all but eliminate any chemical cleaning requirement. Are you chemically cleaning based on a predetermined frequency or a condition assessment (the presence of mineral scale)? I would not recommend perfoming a cleaning procedure unless there are...
  5. puigi

    A181-I Flange Rating

    The ASTM A-181 specification is a standard for carbon steel forgings general purpose piping. Are you sure that is the correct specification for the flange material in question?
  6. puigi

    Ob-round Fire Tube Flange Design for Treater

    ASME Section 1, Part PFT, Para PFT-20 (Attachment of Furnaces).
  7. puigi

    Replace of boiler's pressure relief valves

    Javier: An organizatrion with an R stamp should be capable of performing the welding required to install the new valves in place, but not any adjustments or calibration of the new valves, this would require VR certification. I recommend you consult with the valve manufacturer, they may...
  8. puigi

    11" X 15" Elliptical Handhole Gasket Failure

    Mab: I have not had to re-enforce any doors. If you are concerned that the door may not be able to take the force required to achieve the necessary compression for the spiral wound gasket material, there are some other wire impregnated graphite gasket materials that may meet your needs, grafoil...
  9. puigi

    11" X 15" Elliptical Handhole Gasket Failure

    Seat taper and seating area overlap are important dimension on that design may-way. If you have or could obtain the original drawings with the man-way seat and door dimension that would be helpfult to determine if excessive seat taper is the cause of your problems. Ensuring that the door is...
  10. puigi

    Boiler tube Analysis

    Champion: The RVI would be during the next outage, that is why I stated soonest available opportunity. High boiler water chloride levels increase the propensity for carry-over, not scale formation; choride ions are inversely soluble. Typically at that low of a chloride level, carry-over is not...
  11. puigi

    Pressurized Vessel with PH Sensor and Level Indicator

    Another option for level monitoring and control: http://www.vegacontrols.co.uk/vegapuls_radar_index.asp?fixedRangeID=01 For pH monitoring, you may have to draw a small continous samle from the process and cool it before sending it to the probe.
  12. puigi

    Boiler tube Analysis

    Champion: What do you mean by the term "off spec"? Was there actual contamination of the feed-water with scale forming minerals, or were the residual treatment levels in the boiler-water out of the desired control range by 10%? Do your operators test for either turbidity, total dissolved solids...
  13. puigi

    Electric boiler with highly variable pressure

    Rather than purchasing this specialized equipment for limited use, have you considered using an existing testing facility that meets your requirements? The organization I used to work for has a steam testing facility in Philadelphia that may meet your needs. I know they've performed testing for...
  14. puigi

    Electric boiler with highly variable pressure

    Are there any steam purity requirements for the process, will it have to be superheated? If there is, it may make you available selection pool even even more narrow. I've used small oil/gas fired forced flow steam generators (Vapor & Clayton) along with an accumulator for PRV testing in the...
  15. puigi

    Clarifications of Sec 1 Boiler code for discharge valves and piping

    Bsquared: ASME Section I accepts ASME Standard B16.34 for valves within the boundaries governed by this section of the code. See PG-42.1.12 & PG-42.2.
  16. puigi

    Reclassification - Section I to Section VIII, Div. 1

    ASME code case 1855-1 (Dec 30, 2006) may apply to your case.
  17. puigi

    Tube to Tubesheet Joint Question

    What code of construction are you using? Typically expansion is performed prior to seal welding.
  18. puigi

    ASME Sect 1: Pneumatic Test in Lieu of Hydrostatic Test

    New construction or in-service, what is the test for? Pneumatic test or volumetric NDE may be acceptable, have you consulted with your AI?
  19. puigi

    weld repair

    SA-105 is a material specification for forgings in piping applications. The material specification I listed in my earlier post was incorrect. The correct material specification is A-182A -A-182M (SPECIFICATION FOR FORGED OR ROLLED ALLOY AND STAINLESS STEEL PIPE FLANGES, FORGED FITTINGS, AND...