  1. radwin

    Ph diagram

    I started to plot the temperature and pressure in the ph diagram r22. how could this help analyze in the diagnostic of the system. Thanks. Appreciate any response.
  2. radwin

    suction line

    What is the effect if the piping guidelines in the split type air-conditioning unit is 5/8,3/8 inches, but you installed 3/4, 3/8 inches of copper tube. thanks!
  3. radwin

    ceiling return

    Thank you for all the replies. I got a lot of insights. I appreciate all of your time. Thanks!
  4. radwin

    ceiling return

    I mean ceiling return with a roof above the ceiling. most ceiling return with a drop ceiling that I see are between floors not below the roof. is it because the space below the roof and above the ceiling has more heat load?
  5. radwin

    ceiling return

    is it advisable to have ceiling return at the roof with insulation? Because I imagine it also have heat load.
  6. radwin

    sling psychrometer

    does a thermometer with a wet wick then subjecting it to a fan can replace a sling psychrometer?
  7. radwin

    CFM rating of outdoor unit

    @ Mint Julep, it means that the it is better to design the exhaust capacity cfm bigger than the total cfm of the outdoor units and place the outdoor units a distance from the inlet grill to have a steady flow since you said that it has no effect in the fan of the outdoor units and it has more...
  8. radwin

    CFM rating of outdoor unit

    guys what i mean by draft is pressure, I fear that there will be pressure in the exhaust fan if the capacity of exhaust fan is lower than the cfm of outdoor units or there will be pressure in the fans of the outdoor units if the fan of the exhaust is greater in capacity than the outdoor units...
  9. radwin

    CFM rating of outdoor unit

    the room is only occupied by outdoor units, about four units. my fear is that if the total cfm of the outdoor units did not match with the exhaust fan of the room there will be a draft in the fans of either of the exhaust or the outdoor units.
  10. radwin

    CFM rating of outdoor unit

    yes the design of the machine room has a fresh air intake and the exhaust fan will take the hot air. my fear is if i can not match the the cfm of the outdoor unit with the exhaust fan there will be a draft. is it very significant?
  11. radwin

    CFM rating of outdoor unit

    What is the cfm rating of an outdoor unit of a 5TR split type aircon unit? If my outdoor unit is inside of a machine room is it necessary to match cfm of outdoor unit with an exhaust fan with a same capacity provided it is the only unit inside the machine room?
  12. radwin

    effect of exceeding maximum piping length in split type aircon

    you mean if the piping limit for example is 60 ft for a 2.5 hp wall mounted split type, the drop in capacity will be significant if you install it exceeding 200 ft?
  13. radwin

    effect of exceeding maximum piping length in split type aircon

    what is the effect when you exceed maximum piping length on split type air-conditioning units? is there a range in exceeding the range in the manufacturer's specification regarding piping length.