  1. seattlemike

    SMRF with HSS?

    Has anyone seen an approval for a HSS Moment Frame connections as a SMRF? I have seen the standard RBS, WUF-W, WUF-B, etc, etc (although they are not all approved), but I have not seen any discussion of HSS as Special Moment Resisting Frames. Any input? Thank you, SeattleMike
  2. seattlemike

    Bar Splices in CMU for IBC are too much?

    WillisV: Hmm... I thought that the IBC 2003 alternate load cases defered to the material standard for 1/3 increase. AISC 341-05 (steel) strickly forbids the 1/3 increase, but NDS (wood) allows Cd = 1.6, and the MSJC-02 section 2.1.2.3 allows the 1/3 increase. ...except in MSJC-02 2.1.2 it's...
  3. seattlemike

    Why does standard Welded Wire Mesh does not meet ACI criteria?

    Yes, I heard the rule of thumb was 3 times the slab thicknes... I wasn't sure if there was still a minimum steel requirement... I'd never heard of one... just the better-than-nothing W1.4xW1.4 - 6X6 WWM.
  4. seattlemike

    Bar Splices in CMU for IBC are too much?

    Yep, looks like I will have to get my hands on IBC 2006 as soon as possible to solve all my cases. I have a lot of edge bars and 3500 psi masonry... with both 80% bars and 100% bars... Is the 1/3 increase for Masonry still in IBC 2006 and MSJC-5, aka ACI 530-05/ASCE 5-05/TMS 402-05? Thank you...
  5. seattlemike

    Why does standard Welded Wire Mesh does not meet ACI criteria?

    WillisV, So where are the minimum requirements for slab-on-grade? Seems like it's just owner/geotech preference? Mike
  6. seattlemike

    Why does standard Welded Wire Mesh does not meet ACI criteria?

    Hello fellow Structural Engineers, This may be a dumb point, but 6x6 - W1.4xW1.4 WWM comes up woely short of the ACI requirement of 0.0018.... in a 4" slab, WWM = 0.28 sq in/ft, but ACI requires 0.0018*4*12 = 0.0864 sq in/ft. what's that all about? Why does standard Welded Wire Mesh that we...
  7. seattlemike

    Bar Splices in CMU for IBC are too much?

    We are using IBC 2003 and ACI 530-02. Hmmm.. yes, I will see if the ACI 530-05 is available. Thanks Boiler8019!
  8. seattlemike

    Bar Splices in CMU for IBC are too much?

    I agree, seems like #6's are on the out unless you go to couplers... which probably isn't so bad.
  9. seattlemike

    Bar Splices in CMU for IBC are too much?

    Hello fellow structural engineers, Several years ago, I think I went to seminar on the UBC transition to IBC, and it mentioned this problem with Masonry, and I am just now running into it: IN the WSD design method: IBC has an equation for lap splices that overrides ACI 530, and for #5 bars...
  10. seattlemike

    Aluminum pole in Concrete?

    Hi UcfSE, Is there a difference between "asphaltic" coating and "bituminous" coating?
  11. seattlemike

    Aluminum pole in Concrete?

    Do standard Aluminum structural shapes/alloys have a problem (chemical) with being embedded in concrete? Thank you, SeattleMike
  12. seattlemike

    lawsuits over Seismic or Hurricane damage (rewrite)

    Hello fellow Structural Engineers, I am a licenced and practicing structural engineer in Washington, and I am doing research into lawsuits that have been brought against us for damage due to earthquakes or hurricanes. However, I am having trouble finding any cases where this has happened...
  13. seattlemike

    window failures: enclosed v. partial enclosed?

    well, after one failure occurs (anywhere), the increased internal pressure causes additional failures at the walls and the roof... it only takes one, then, it all goes to 'partial enclosed' and typically, roofs/ceilings, other windows, etc, get blown out. the SEAW RSM seems to indicate high...
  14. seattlemike

    Florida Building Code: Partially Enclosed v. Enclosed

    The 50 year reference could be just a number to give people something quantifible in their lifetime, and it may be that the Snow, Wind, and Earthquake folk just copied each other for consistency. But nonetheless, it envokes the concept of a duration of time for which we design, although I'm sure...
  15. seattlemike

    Florida Building Code: Partially Enclosed v. Enclosed

    My impression was that our buildings were built for a 50-year lifetime, based on the way the Wind, Earthquake, and Snow codes are written. Also, if you do not protect the windows, you would want to design the building as "partial enclosed." See the discussion in C6.5.11.1, pg 290, of the ASCE...
  16. seattlemike

    window failures: enclosed v. partial enclosed?

    By failure, I mean that they will be sucked off the building, or be blown inward. So, positive or negative pressure failure. I'm not sure which is more common: Judging from ASCE-02, I'm guessing it's negative pressure, as the negative wall pressures are typically higher. From SEAW-RSM...
  17. seattlemike

    window failures: enclosed v. partial enclosed?

    Windows are typically designed for a failure rate of 8 or 9 in 1000, that is less than 1%. However, in modern buildings that are complete curtain walls, each side might have several thousand 2x4 windows in the curtain wall... and typically a few fail... so, that would make one think that ANY...
  18. seattlemike

    Florida Building Code: Partially Enclosed v. Enclosed

    It appears that per ASCE 7-02, C6.5.9, pg 285, glazing above 60 ft needs to be protected as well: more exactly, we need to protect windows that are 30 ft or less above neighboring building roofs. C6.5.9 clarifies that any building roof within 1500 ft (horizontal) needs to be evaluated for...
  19. seattlemike

    Florida Building Code: Partially Enclosed v. Enclosed

    Hello Structural Engineers, Question on the Florida Building Code, in the Wind-Debris Zone (but NOT the High-Velocity Hurricane Zone): Our firm is designing a 7-story office space-parking building in downtown Cape Coral, Florida. Still waiting to hear if it's exposure B or C. The architect...
  20. seattlemike

    What is HVHZ in Florida 2006 code?

    What is the definition on the High-Velocity Hurricane Zone in the Florida 2006 building code? Over 130 mph? 110 mph? Thanks, Seattle Mike