  1. gaux

    maximum temperature on a bearing on electrical motor

    I have a 3.5 MW motor, syncronous, with two sleeve bearings, (zoelern manufacturer) and i have temperatures up to 93 º C, and the manufacturer of the motor, says me that i could put the alarm temperature on 95ºC and the stop on 100 º C, this seems to be too high, does somebody knows about some...
  2. gaux

    select gen set for start pumps

    and if we use a soft starter for each motor?
  3. gaux

    select gen set for start pumps

    where could i get a sizing program on internet? yes, my mechanical calculations,talks me on 2193 kva, and 1500 kw nominal, but if i get all except one, in example 450 kw i get with the starting current a 3,8 MVA... how could i size the gen set? i don´t know....
  4. gaux

    voltage droop calculations

    how could i calculate the voltage droop? maybe i use Xd in example 10,9 ohms, and i multiply by current?
  5. gaux

    select gen set for start pumps

    ok, but i´ll like to know your opinion. thanks in advance
  6. gaux

    select gen set for start pumps

    hi, I want to start up 3- 300 kw (272 start up current cos 0,7) motor, 1- 90 kw ( 68 A start up current, cos 0,72), 1- 450 kw ( 396 A start up current cos 0,7) and the voltage is 4160 Volts... we are thinking on starting up with direct start and a generator driven by a diesel motor. thanks...
  7. gaux

    starting a 700 kw with a VFD of 180 kw

    yes, thanks a lot, i´m just a mechanical and i don´t know so much about this questions...for this i appreciate your opinions thanks
  8. gaux

    starting a 700 kw with a VFD of 180 kw

    yes, i could keep propulsion on 0 pitch till i have the full speed,
  9. gaux

    starting a 700 kw with a VFD of 180 kw

    hi, thanks for your always good ideas, now i just thinking on a new project on my table, that´s a motor that moves a propeller, that start on pitch 0, and i have calculated the mechanical losses.. and they are 116 kw´on 1600 rpm, the idea is to run the motor without load till 1600 with VFD (with...
  10. gaux

    VFD switched frequency

    I have a problem with a VFD and a syncronous motor permanet magnets (10 kw 100 hz 400 V), i had asked before some tips, now i could start up without flashing... with a 10khz,the motor have electrical arc between rotor and stator.... and then, i reduce to 3 khz the electrical arc dissaperar, but...
  11. gaux

    different currents on the parallel wires of a phase

    120mm^2 that´s 6 cables for each phase, and three phases... total cables 18 thanks for your attention,
  12. gaux

    different currents on the parallel wires of a phase

    120 mm per wire, and they go together by a cluster,
  13. gaux

    different currents on the parallel wires of a phase

    ok. i forget to mention, i got 2 units else, and they are more or less shared, little diferences... 5 amps or so, but i don´t know if the manufacturer of the wire is the same... the section, yes.
  14. gaux

    different currents on the parallel wires of a phase

    and about this.... about geometric configuration, what could be the expected difference in the worst situation? i don´t know if this could be mesasured or calculated?
  15. gaux

    different currents on the parallel wires of a phase

    maybe if the installer used a cheap wire? this theorical resistivity would change? do you think this is cause of resistivity of cooper? and yes... i see the wires going out of the generators connection box and then go through the floor till the bus bars.... and seems to be the same, except that...
  16. gaux

    different currents on the parallel wires of a phase

    and what does the electrical code says about this? cause i want to ask the guy that do the installation...cause now the supervisor didn´t accept us the instalation.....
  17. gaux

    different currents on the parallel wires of a phase

    But my question is why this difference? cause the lenght is more or less the same, maybe mutual inductance? could somebody explain this mechanical guy this?
  18. gaux

    different currents on the parallel wires of a phase

    yeah, i have no pic, but the distance is the same, they go to the same bus bar and in the other connection point, they goes to the same bar... what is the difference on distances that make a difference of 60 A.? the distance between generator and bus bars are 100 m.