Solved the problem, I had specified a too small exterior tolerance, changed the value from 0.01 to 0.05 and it worked fine. I used assembly set definition and put in the set name under driving region.
Sami
I tried both assembly and part definition. None of them worked. The manual tells that when using part definition the whole set name should be put in e.g. "assembly-1.part.etc..." and when using assembly definition it should be enough with just the name of the set.
Sami
Hi!
I'm trying to do a simple submodel analysis of a flange connection. I have run the global model but when trying to run the submodel I run into some problems.
The problem is that in the contact area between the two flanges I have two nodes, one node on each of the flanges that share the...