  1. Nick4684

    How long centrifugal pump can work on minimum flow for commissioning purpose?

    Thank you guys for all of your valuable inputs, I double checked with vendor as well, there is possibility of temperature increase if pumps run for long time on the min flow, as you already mentioned; So it seems, there is no point for running pump for more than 30' just to have a general...
  2. Nick4684

    How long centrifugal pump can work on minimum flow for commissioning purpose?

    @1503-44: correct, just on recycle mode @Artisi: correct, all the supposed testing and data will be collected at a restricted minimum flow
  3. Nick4684

    How long centrifugal pump can work on minimum flow for commissioning purpose?

    yup, 100 m3/hr go directly to suction header 16" pipe.
  4. Nick4684

    How long centrifugal pump can work on minimum flow for commissioning purpose?

    Thank you all guys for provided responses, flow will be controlled by FCV (flow control valve). It is not bump test- I am going to do Mechanical Run Test to see pump performance, vibration, temperature, Current etc. when pump working on min flow (100 m3/hr) discharge of pump would be 100m3/hr...
  5. Nick4684

    How long centrifugal pump can work on minimum flow for commissioning purpose?

    @ LittleInch Thanks for your advise, I did MRT for almost the same size pump/ same arrangement on minimum flow for app. 2hrs without any issue, ( I checked pump temperature every 10'); but according to our procedure and client request, MRT should be done in 4hrs, however, as "Artisi" mentioned...
  6. Nick4684

    How long centrifugal pump can work on minimum flow for commissioning purpose?

    Thank you all for your useful response, Sorry for delay to response; I had some personal problem:) Medium is water, constant speed electric, on Flow Control, it is recirculating to the suction pipe and full suction pressure is available- suction pressure is 20 bar . The reason of testing on...
  7. Nick4684

    How long centrifugal pump can work on minimum flow for commissioning purpose?

    Normally we are doing 4hrs MRT (mechanical run test) for commissioning of pumps. Now I have pump, 400Kw- 350m3/hr, (min. flow 100m3/hr)- 50bar discharge pressure and 260m head any idea for how long can I run it for MRT on minimum flow line to check pump overall performance, vibration, temperature?