  1. dave11282

    3G router

    VE1BLL that Cradlepoint looks fine, @ £200 , is a snip thanks
  2. dave11282

    ship supply

    hi apologies if this covered before, we have a 440v, 3 phase, 60hz supply on ship, motor control panel , using a 440v/230v transformer, to supply lighting circuit, should this the '0v' of the secondary be earthed ? ( ie wire connected from 0v to chasis of skid, control box ?) thanks
  3. dave11282

    3G router

    Hi I need a competitively priced 3G router, which can be configured for VPN, Ipsec , etc anyone recommend good quality price, is for industrial application thanks
  4. dave11282

    SLC500 to E1100

    Hi I need to connect a Bradley SLC500 to E1100 HMI, over ethernet, can anyone give me links to application notes , how to set this up thanks
  5. dave11282

    Tri rated cable hazardous area

    Hi can standard tri rated cable be used in an EExd enclosure ? think zone is zone 1 thanks
  6. dave11282

    medium voltage switch?

    many thanks guys application is for a marine cable that is being terminated at shore, I believe it is some kind of data carrying cable, at the minute Tyco and rossengineeringcorp looks good, any more welcome, many thanks
  7. dave11282

    medium voltage switch?

    hi I am trying to source a medium voltage switch, 3 pole, able to work at 3.6kv, 320mA. any ideas appreciated thanks
  8. dave11282

    Ozone detector?

    Hi all I need an ozone sensor with a 4-20mA output to PLC please can anyone recommend any UK maufactures'/suppliers thanks
  9. dave11282

    CAD Drawings?

    Marmite thanks for link Dave
  10. dave11282

    CAD Drawings?

    Hi all I am trying to source some CAD drawings for Schneider (Merlin Gerin) distribution boards Isobar 4 16 way 3phase? (I did contact Schneider, but they 'could not find any'!!) they must exist somewhere on some server somewhere, any pointers would be great thanks
  11. dave11282

    Mitsubishi FX3U and Westermo Modems Problem

    we had huge issues using westermo modems last year, TDW33 they have had firmware issues, the swedes rehashed all their kit, and it was not properly tested, in the end we set the HMI with a PPP connection, connected to FX3u in transparent mode. Key point with PPP is that all nodes have same...
  12. dave11282

    switching neutral in single phase motors?

    thanks for replies. I didnt think there was a BS standard. UK generation is 240V. EU requirement for single phase harmonisation is 230V. UK still generates 240V. And is unlikely to change due to huge implications on generation network. Dave
  13. dave11282

    switching neutral in single phase motors?

    Hi all are they any BS standards that state that it is recommended or must switch the neutral (so the neutral is taken thru a set of n/o on the motor contactor) as well as the phase to a single phase motor 240v motor? thanks Dave
  14. dave11282

    RCD and 0.75kw motor?

    we also noticed that the new TEC we had in was now wound differently to the one we evaluated. Which surprised us! The connections are different in the motor terminals. Same 0.75kw spec / chassis ? Dave
  15. dave11282

    RCD and 0.75kw motor?

    many thanks guys, Jeff, I did carry out IR test, 800 meg ohm. Do you have URL for TEC? thanks Dave
  16. dave11282

    RCD and 0.75kw motor?

    Hi all I am using a single phase TEC 0.75kw motor on 240v 50Hz UK supply. every time we drop the supply to the motor the 30mA RCD trips? I know motors can be electrically noisey, but is there a simpler way around this apart from upping the RCD to say 100mA?? Does anyone know where TEC motor...
  17. dave11282

    Brass contacts?

    dpc "I might be a little concerned if this was an application where the contacts stayed open for years and years, then had to work reliably when closed. But if the contacts close once in a while, you're probablyh OK. " this is my concern, the 'contacts' are open, because it is an inhouse...
  18. dave11282

    Brass contacts?

    itsmoked, thanks, cant find any real adverse info from web searches for brass, my only thought is similar to yours, where the plunger/plate could beacome tarnished over time in an external environment, and possibly create a high impedance contact
  19. dave11282

    Brass contacts?

    dc = direct current switch rate = milliAmps not full submersion only rain water is a lift shaft no gases
  20. dave11282

    brass contacts?

    Hi all, we use a design where we have open face brass contacts for level switching control in a shaft, we now want to make our product suitable for external use, my concern is the possible reaction of this material and rain water, the brass switch plates/plunger carry 24v dc, are there any...