vibration peak value during FFT obtained at 1 x rpm means unbalance or misalignment.
overall vibration (frequency range 10 to 10,000Hz) obtained as 5 mm/s rms. FFT analysis showing only one pick of the same measuring point as 0.5 mm/s rms at 1 x rpm. obviously the magnitude of the vibration...
I am in-charge of condition monitoring of our power and desalination plant since one year. I have ten years experience of maintenance but one year of cause diagnosis of vibration, which is not enough, however I have accepted the challenge.
When our organization purchased a vibroport-41 from...