  1. jodin38

    Issue with change in results in NX NASTRAN

    I have found that setting results desitination to 'Print' produces a results file in .f06 format, where as 'PostProcess' produces a results file in .op2 which is required for GFB (NX NASTRAN User Guide states that grid point force data is not in the .f06 file) If 'Print and PostProcess' is...
  2. jodin38

    Large # of Subcases - Way to output case w/ Max Stress in a Element?

    It depends on which preprocessor you are using. There is an option, for example, that I have used in FEMAP v9.3 where you can run multiple load sets, and then ask for an 'envelope plot' showing both the maximum stress from the critical load case and also which load case is producing the...
  3. jodin38

    Issue with change in results in NX NASTRAN

    Hi I am using FEMAPv9.3 with NX NASTRAN to carry out an analysis, and want to interrogate the model for Grid Point Force Balance results yet have hit quite a bizarre issue. My intial analysis was carried out and the output results destination set to 3.Print and PostProcess in the Nastran...