  1. weirweb

    API-510 Vessel Alteration

    We have a 25 gallon vertical code vessel (with R stamp)that was fabricated without a jacket. We want to add a steam heating system on the bottom third of the vessel. We want to wrap 3/8" copper tubing around the tank. In order for us to do that, we need to remove the namplate (which sticks out...
  2. weirweb

    Dewatering Equipment?

    I presently have a polymer water desolventizer unit that I take my product from. I then take it over to my Hobart 4146 meat grinder which acts as a dewaterer and compacts my polymer to a size that is great for drying. The screw in the meat grinder has rusted out. Hobart does not make the...
  3. weirweb

    Painting standards

    Can anyone point me in the right direction for codes or standards on painting within Chemical Plants? Specifically, I am after piping paint requirements and color schemes. Thanks.
  4. weirweb

    Pressure relief header design

    Art, Thanks for your time. Your keen piping sense is a hard trait to find. My pipefitters will be challenged, but they need it anyway.
  5. weirweb

    Pressure relief header design

    Can anyone point me in the right direction for correct piping design on relief headers? Specifically, the preferred method for entry into the header. Top entry versus 45 degree lateral entry? I do not need specifics on back pressure or relief valve design. Thanks
  6. weirweb

    Valve selection for BF3 service?

    Any recommendations of valve manufacturers for BF3 service would be helpful. I am familiar with Superior and Ewal.
  7. weirweb

    Valve for BF3 Service?

    Any recommendations of valve manufacturers for BF3 service would be helpful. I am familiar with Superior and Ewal. Thanks.
  8. weirweb

    Electrocoalgulation

    Electrocoagulation through the Powell Water Systems reaction chamber produces several distinct electrochemical results independently. These observed reactions may be explained as: A. Seeding resulting from the anode reduction of metal ions that become new centers for larger, stable, insoluble...
  9. weirweb

    Which type of strainer is better for CO Cold box?

    Generally, Y-strainers are used with gases such as steam or air. Basket strainers are used with liquids. A Y-strainer will offer more pressure drop than a basket strainer since its free straining area is less. As a strainer becomes clogged to the point where the OAR of the strainer approaches...
  10. weirweb

    ERW versus Seamless Boiler tubing

    I agree that these operating requirements are not very demanding. Can you tell me what OD and wall thickness the tubes are? Without a superheater, corrosion and expandibility should not be a problem, allowing for even re-design of the tube arrangement. Heat transfer should vary between types...
  11. weirweb

    AutoCad LT WMF export problem

    I have found a very simple way to accomplish what you desire: By turning all lines into PLINES, you can then use MPEDIT (Multiple Polyline Edit) and increase the width of all selected lines within AutoCAD. Once this is done, you then export your selected drawing as a .wmf file. Once in Word...
  12. weirweb

    Bubble Cap Trays in Dirty Service

    You might want to look into a tray with a three-dimpled periphery to minimize contact with the tray deck for fouling or corrosive conditions. One place I know of: http://www.koch-glitsch.com/koch/products/flexitray_trays.asp
  13. weirweb

    How do you clean your heat exchanger

    Usually the pressure is for the rating of the tube. In our case the exchanger has even seen some polymer buildup. We connected our hot cyclohexane to the exchanger. It cleaned the exchanger with ease. I have heard of a material called GRUBs which works very well and does not need to be...