  1. KirkGH

    Special Inspections for 5/16" or less fillet welds

    The 2009 IBC states 1704.3 Exception 2.1 that Single pass fillet welds not exceeding 5/16" in size do not require continuous inspection. Since IBC defers to AISC 360-10 Chapter N I can't find an exception to continuous special inspections for small fillet welds in Chapter N. Can somebody help...
  2. KirkGH

    Cable Analysis for a Backstop Net

    I think I may have found a book that proposes a method of analyzing cables. Others may find it of use but its math looks to be beyond my capabilities. Cable Structures by H. Max Irvine. I found it on www.ScribD.com. This is my first introduction to the website and it appears to have some...
  3. KirkGH

    Cable Analysis for a Backstop Net

    Ok dhengr and BA, thanks for your time. KGH
  4. KirkGH

    Cable Analysis for a Backstop Net

    "Thus the shortest secondary cable near the midspan of the primary cable will be approximately 25' long." Good point, that is a significant error. However, wouldn't the length of the secondary cable be closer to 36.9'- 6'=30.9' (not including sag from the primary cable at the north end)? "so...
  5. KirkGH

    Cable Analysis for a Backstop Net

    For the wind load we're taking the net surface area/gross area to get a percentage of wind (12%). Know of any better way? KGH
  6. KirkGH

    Cable Analysis for a Backstop Net

    Thanks Eric. Do you know if I can assume a higher sag condition with for wind loads that at service loads? Let's say I want to keep the sag at 1'-0" for typical conditions but when the wind blows for a 90 mph wind load it can sag for 6 feet. Will the structure have any give to it? KGH
  7. KirkGH

    Cable Analysis for a Backstop Net

    I've read through the posts on cables and gathered that the most appplicable equation to use to analyze the the attached schematic is wL^2/8=TH. T = tension in cable H = amount of sag in cable The attached diagram shows the support for a net suspended over some bleachers. The net spans 6 feet...
  8. KirkGH

    ASCE 7 Ice Load Provisions for Netting

    That means for my net for one thread I have 1.28 lbs/ft. With 1 3/4" x 1 3/4" spacing I end up with roughly 17.6 psf LRFD, 12.3 psf ASD. Thats 1 1/2 gallons of water on each square foot of the net. Aye carumba. Thanks for the input. KGH
  9. KirkGH

    ASCE 7 Ice Load Provisions for Netting

    I need to figure out the ice load on some netting but am getting a nnumber that can't be correct. The equations are straight forward. ASCE 7-10 by the way. t = 0.5" Vc = 30 mph temperature = 15 degrees Farenheit Kzt = 1.0 Ii = 1.0 Dc = .0945 in. Per 10.4-4 fz= 0.980 Per 10.4-5 td = .98 inches...
  10. KirkGH

    HSS Column Selection for 4 Story Structural Steel Building

    The HSS criteria came from the engineer above me. Ease of tying in cold formed steel studs and cleaner connection details around an HSS is one reason, architect preference another. The project started with W columns and has switched. Not sure on the exact reason why but I'll get clarification...
  11. KirkGH

    HSS Column Selection for 4 Story Structural Steel Building

    I've been tasked with designing columns for a 4 story building (interior columns only, the perimeter is concrete tilt wall). Story Height: 15 feet Floor: Vulcraft VLI composite slab/metal deck with open web steel joists and wide flange steel beams. Roof: Metal Deck Column Shape: Square HSS...
  12. KirkGH

    Cold Formed Steel: Simple Clip Beam Connection Design

    wannabeSE: Detail A is independent of B and C. They are two separate questions: Thanks for the link. I've looked further into the required bearing condition and it looks like AISI 2001 Eq. C3.4.1-1 web crippling capacity calculation is only valid for bearing lengths >= 3/4". This eliminates...
  13. KirkGH

    Cold Formed Steel: Simple Clip Beam Connection Design

    For architectural reasons it's better to turn the cees in the direction shown in the attached document. My concern is buckling of the clip angle. Is this wise? How do I calculate the capacity of the clip? As best I can tell I could approximate the condition conservatively as a cantilever to get...
  14. KirkGH

    WRI/CRSI Design of Slab-on-Ground Foundations Deflection Calculation Example

    Does anybody have an example of the deflection calculation for WRI/CRSI Design of Slab-on-Ground Foundations method? I've got a company spreadsheet that had errors and is now (conceivably) corrected and I want to verify my results with a worked out example but can't find one. The calculation, as...
  15. KirkGH

    IBC - Stair Guardrail / Handrail Requirements

    Thanks for the responses guys. Doesn't look like there's any detractors. My supervisor had approved my design already, but I was having second thoughts and am trying to double check everything. Kirk G Hall, PE
  16. KirkGH

    IBC - Stair Guardrail / Handrail Requirements

    I'm working with a client who had code enforcement tell them their stair handrails needed to be "brought up to code." My interpretation is that any and all modifications need to be made to meet IBC 2009 (current city adopted code). My client thought that just meant adding pickets to create a 4"...
  17. KirkGH

    Compression vs Compressive Strength

    σ = P/A gives the stress (psi) for a member of a certain area loaded axially. Δ = PL/AE gives change in length of a member when loaded axially. For a given cross section, A, the failure load is equal to σ*A Also, by algebra: Δ = σL/E Set σ = 3,000 psi and 1,000 psi in the above equations to...
  18. KirkGH

    Repair of Corroded Tube Column Bottom and Base Plate

    I thought about the trim wood piece. It seems like it would just slide off; analysis-wise the shores would need lateral support normal to the slope of the diagonal. I like the gist of it. I thought of an idea to weld on a capped HSS 5 x 5 to the underside of the diagonal to provide for...
  19. KirkGH

    Repair of Corroded Tube Column Bottom and Base Plate

    Some additional repair may be required after looking at the pictures again. Comments? Kirk G Hall, PE