Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: PrinceOfAll
  • Order by date
  1. PrinceOfAll

    Pipe sizing question regarding admittable pressure

    OK guys, I have revised my unit conversions; the diameter 28 mm will be suitable. Also a corresponding thickness 1.5 mm will withstand the pressure.
  2. PrinceOfAll

    Pipe sizing question regarding admittable pressure

    I am sorry cikiste, I've forgotten to tell you that the pressure you substitute in the design equation should be absolute pressure not gage pressure . So please resolve the problem using 26 bar pressure instead of 25 bar.
  3. PrinceOfAll

    Pipe sizing question regarding admittable pressure

    Hello, The fluid pipe sizing is usually based on the fluid velocity. For liquid pipes the recommended velocity range is from 1-3 m/sec. If the velocity is much less than 1 m/sec, this will allow the precipitation of the solid particles in the liquid. On the other hand, the very high liquid...