Yes. I spoke to the forman from a project completed in phil Pa. The cages were spliced. The only problem in picking the cage were the csl tubes. The first pick the cage bent enough to bend the csl tubes within the cage. The picks were adjusted and no other problems encountered.
In that area Cook Drilling Corp installed 4 130' cages in 6' diameter holes, loaded with csl and o cell equipment. I believe they made a custom jig out of smaller pipe, and had two cranes involved
Thanks Zambo, that may be solution to the problem. Focht3 the reason flow able fill is not a practical method of backfilling is cure time and placement. The engineer on this project requires 24 hours of time previous to pouring concrete. There are about 800 total holes on this project. The...