Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations IDS on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. georgeverghese

    Flue Gas Scrubber Design Database

    Speak to the folks at Norton or Koch in the USA who manufacture all sorts of packing for absorber / stripper columns. I dont seem to see Norton USA on Google - its all contaminated with links to China companies.
  2. georgeverghese

    Pipeline transporting Naphta and jet fuel

    If this corrosion is internal, then you will have the same problems with above ground lines as with the old underground lines. Got salty water in these fuel grades at the source tanks ?
  3. georgeverghese

    Axial Control Valve Sizing

    The quoted "min Cv" in that table of 11 for the 12inch valve implies a rangeability which far exceeds the typical value of 30, since 1875/11 = 170. Hence I would interpret the min Cv of 11 as being that for mechanical integrity and not for controllability - see footnote to those tables. Hence...
  4. georgeverghese

    Axial Control Valve Sizing

    Sizing control valves for the min flow case is an integral part of control valve selection, and often overlooked by process and instrumentation engineers. The end result is not good if ignored - poor controllability at low flow resulting in frequent shutdowns / unsafe operating conditions /...
  5. georgeverghese

    Axial Control Valve Sizing

    The turndown case will also have to be accommodated, which I guess is : P1 = 82barg,P2=36bar, Q=10e3sm3/hr. The resulting Cv must be higher than the min permissible Cv as recommended by the control valve vendor. From this table, say for 12inch valve, the min Cv for the case of equal %, multipath...
  6. georgeverghese

    Compressibility of Nitrogen Gas and Liquid Water

    Linear extrapolation from 500bar to 655bar from that table 2-179 in Perry gives z=1.54
  7. georgeverghese

    Compressibility of Nitrogen Gas and Liquid Water

    This is where I got the solubility curve for N2 from https://www.thermopedia.com/content/1138/ I havent been able to get a cross reference check ( so far) to this graph elsewhere at these high pressures. H shows a pressure dependence at high pressures. And the z value was calculated from the...
  8. georgeverghese

    Compressibility of Nitrogen Gas and Liquid Water

    Accounting for N2 solubility in water at 655 barg, Google tells me H = 6e-5 / MPa, where solubility of N2, the Henry's Law constant, is expressed as mole fraction of N2 / kgmole of water. Simplifying, this works out to 6.2kg of N2 dissolved / m3 of water. Add the corresponding mass dissolved in...
  9. georgeverghese

    Compressibility of Nitrogen Gas and Liquid Water

    Compressibility factor z is roughly 1.61 for N2 at this high pressure from T-S diagram of N2 in Perry Chapter 3 Find n n=P.V/z.R.T n= kgmoles of N2 gas V= actual volume of gas space in m3 P=pressure = 656e2 kpa abs R=8.314kJ/kgmole/degK T= 300degK Actual mass of N2 required, kg = n x 28...
  10. georgeverghese

    NATURAL GAS COMPRESSOR

    You're off to a good start, this gas is probably not at or below water or hydrocarbon dewpoint. Pistons with labyrinth type piston rings last much longer than those with conventional piston rings, but such machines carry a CAPEX premium, but these payoff very well in the long run with increased...
  11. georgeverghese

    High temp clamp on flow meters

    I set up flow control loops on hot high viscosity bitumen lines running 180-220degC with ultrasonic clamp on FT some 10years ago - cant remember the brand name , but it was some German company - worked as intended. They offered onsite troubleshooting assistance, which was re assuring.
  12. georgeverghese

    Air valve on falling main

    Reverse siphon flow will not be possible as long as the discharge point is above the level at the inlet. Besides, you still got the check valve on pump discharge. In my experience, gravity flow lines in down flow should have this air valve at the top of the high point - this is to let air INTO...
  13. georgeverghese

    Air valve on falling main

    Can you describe this discharge ? "The pipe will be discharging into the gravity network." If this discharge is into a liquid flooded pipe or tank, then I see the justification for this air valve.
  14. georgeverghese

    Flare line connection

    Pls ask a process engineer familiar with hydraulics in this flare network - there are many variables that will affect choice of location where this tie in should be made. You wont find this guidance in B31.3. By the way, how many levels of flare do you have in your plant - LLP, LP, HP etc?
  15. georgeverghese

    Pump piping Layout

    Maybe a side tap off the suction header to the lateral leading to pump A, instead of a bottom tap? With pump sets in HT fluid service, where autostart of the standby pump is enabled, there is usually a warming line in operation on the discharge side of each pump that bypasses the discharge...
  16. georgeverghese

    API 676 MULTIPHASE PUMP MOC & NPSH

    Disappointment and chaos waiting in the wings in this rainforest - screw type MPP with solids in the feed. Good luck to your project managers.
  17. georgeverghese

    Allowable Overpressure for Electric Steam Boilers per ISO-4126

    If your exit piping is short and developed backpressure is < 10% of PSV set press, then also apply a max permissible exit velocity of 0.5Mach
  18. georgeverghese

    EPC Contractor Needed – Gas Compressor Revamp & Gas-Lift System Upgrades (20+ yr-old Unit)

    Since you plan to move from oil seals to dry gas seals on K303, and given the low mol weight gas service requirement, it is most likely new compressors will be required to operate with the existing GTs' for these machines. Compressor rotor fouling may require changeout of demisting devices on...
  19. georgeverghese

    Foam Glass Insulation - fire case

    See the footnotes on that F factor table in API 521- will your foam glass insulation remain intact with high velocity fire hose jet stream ? If not, go for this insulation which is typically used in the oil/ gas business to enable taking full credit for its insulation during a pool fire ...
  20. georgeverghese

    Bernouilli in vertical pipes

    If the exit is in free air, then the downcomer will be in 2 phase air / water flow