  1. C

    MAT FOUNDATION - Not able to reduce the Soil pressure by increasing depth of Mat foundation.

    The subgrade modulus is confirmed by geotech engineer. Its very low for this particular Site. There is nothing the client is ready to do for this particular site.
  2. C

    MAT FOUNDATION - Not able to reduce the Soil pressure by increasing depth of Mat foundation.

    Yes, your understanding is right. The Mat foundation is on clay. The Client is not okay with Pile foundation, Geo technical engineer has given me a soil subgrade modulus of 500, which comes to the bearing capacity of 40kPa. What solution I can provide in this situation. The model is also showing...
  3. C

    MAT FOUNDATION - Not able to reduce the Soil pressure by increasing depth of Mat foundation.

    It's almost uniform. It does not have any peaks. I have attached snip for a quick look. The settlement also looks impractical.
  4. C

    MAT FOUNDATION - Not able to reduce the Soil pressure by increasing depth of Mat foundation.

    I am analyzing Mat foundation using SAFE Model, having a soil pressure of 82 kPa. But the allowable is only 40kPa. I have increased the depth of MAT foundation, yet the model shows same pressure. Can anyone explain me why the SAFE is showing me no change in soil pressure. It will be a great...