  1. akalmand

    meauring vibration on a rotating disc

    Hi all, I am measuring acceleration levels on a rotating disc with the help of 4 accels in axial and 4 accels in tangential direction (90 degrees apart). The intention is to capture wobble motion, and in plane radial motion on the the face of the disc. While I do frequency analysis, I see that...
  2. akalmand

    Looking for explanation into resonance seen in pressure measurement

    Moving on, The next one is a little more complicated for me. I also measured water pressure in the same setup. All details on the attached picture. I used 2 sensors for each line (water in and water out). One mounted right on the water line and the other one using 12 inch hose. For 12 inch...
  3. akalmand

    Looking for explanation into resonance seen in pressure measurement

    Gentlemen, Thanks a lot for your inputs. In the attached picture, I have attached the cross-sectional schematic of the hoses that I used for taking air pressure measurements. The cross-section of the fitting going into the hose is smaller comparatively. I have calculated the resonance...
  4. akalmand

    Looking for explanation into resonance seen in pressure measurement

    Strong, Well, with oil, the pressure is 5000 psi and I do not see any resonance with the same length of hose. I have mounted another sensor right at the test piece and that does not show any resonance. I just want to identify what is causing it and how to better explain it. Then later on I can...
  5. akalmand

    Looking for explanation into resonance seen in pressure measurement

    One correction - Oil pressure measures is in 1000's psi and I do not see any resonance after using 1ft long hose.
  6. akalmand

    Looking for explanation into resonance seen in pressure measurement

    Gentlemen, Thanks a lot for your replies so far. I have attached a picture showing differnt measurement setups along with the fft's. Temperature - increases from 130 - 200 C during the runs Mean Pressure - increases from 200 - 350 KPa Resonance is seen through out the run. Can you please...
  7. akalmand

    Looking for explanation into resonance seen in pressure measurement

    I am trying to get dynamic pressure measurement using a strain based pressure transducer (good upto 5000 Hz). I have used 2 different lengths of plumbing (hose) to mount my sensor. While using 12 inches hose, I see a resonance of 228 Hz in my data. While using 7 inches hose, I see a resonance of...
  8. akalmand

    managing cgr file in CATIA

    I am building a surface model in CATIA and saving it as a cgr file to be used later on in the DMU Optimizer work bench. I want to know is there a way to control the size of the cgr obtaines. I mean is there a way to control the triangulation perfotmed on that surface so that I can get cgr with...