Tek-Tips is the largest IT community on the Internet today!

Members share and learn making Tek-Tips Forums the best source of peer-reviewed technical information on the Internet!

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. EngTal

    Overtightening a bolt beyond its recommended bolt load.

    This spec sheet is really helpful. Can you please share its reference. And where are the spec service temps range and bolt material is mentioned?
  2. EngTal

    Overtightening a bolt beyond its recommended bolt load.

    Thank you for your response. I think the tensile area used here is quite small. the studs diameter is 63.5 from which calculated tensile area should be 3165 mm2. using that min yield load is around 2000 kN.
  3. EngTal

    Overtightening a bolt beyond its recommended bolt load.

    What would be the consequence of tightening A bolt beyound its recommended bolt load. The recommended operational bolt load is 430 kN and we are planning to tight the bolt via hydraulic bolt tensioner and approximately achieving more than 670 kN bolt load/bolt. 430kN bolt load is recommended by...
  4. EngTal

    Metal jacketed vs Spiral wound gaskets for Heat Exchangers

    Why metal jacketed gaskets are used in Heat exchanger's' head covers instead of spiral wound gaskets. What is the advantage of double jacketed gaskets over spiral wound in heat exchangers?
  5. EngTal

    Career progression and learning as a Static equipment maintenance engineer

    Actually, I am new to this platform. I thought there would be different people in different forums. Thank you so much for sharing the reference. @Strong, thank you so much for sharing these references. They are quite helpful.
  6. EngTal

    Career progression and learning as a Static equipment maintenance engineer

    Hi, I hope you all are doing well. Recently, I got a full-time job as a static eqp maintenance engineer at a well-recognized company. I needed some guidance on how to improve myself in knowledge and what type of certifications apart from CMRP I should do to progress in my career ahead. For...
  7. EngTal

    Career progression and learning as a Static equipment maintenance engineer

    Hi, I hope you all are doing well. Recently, I got a full-time job as a static eqp maintenance engineer at a well-recognized company. I needed some guidance on how to improve myself in knowledge and what type of certifications apart from CMRP I should do to progress in my career ahead. For...
  8. EngTal

    Leakages in High pressure Urea grade nozzles, lens gaskets.

    Hi LittleInch, Yes, this drip ring acting as a gasket here. It has two sealing surfaces like lens gasket. The drawing and specs of it are mentioned in the link attached. https://www.meccanicapadana.com/intranet/libretti/libretto123-01-1.pdf
  9. EngTal

    Leakages in High pressure Urea grade nozzles, lens gaskets.

    Dear TugboatEng, This is a drip ring. That tapping is an integral part of the gasket. I will attach a picture of it below for your info. This link contains information about Drip rings and lens gasket. : https://www.meccanicapadana.com/intranet/libretti/libretto123-01-1.pdf
  10. EngTal

    Leakages in High pressure Urea grade nozzles, lens gaskets.

    Hi LittleInch, This is a threaded flange on a Urea grade nozzle. Rating is above 2500Lb (special rating for UG). Studs have threads in accordance with ANSI B 1.20.1 NPSM. No, we are not trying to force this into place. I mean there these spools are properly aligned and have minimal or no stress...
  11. EngTal

    Leakages in High pressure Urea grade nozzles, lens gaskets.

    By no tightening margin I meant, the nut won’t further rotate upon striking the spanner. Also the(hexagonal)edges of the nut are getting damaged. A picture of the assembly is attached.
  12. EngTal

    Leakages in High pressure Urea grade nozzles, lens gaskets.

    How to handle a situation in which there is a Urea-Carbamate leakage through a High-pressure Urea grade nozzle and lens gasket. What to do if the tightening margin is finished after hot tightening? What should we take care of during installation to avoid such leakages after plant startup?