  1. Amr Shams

    Inquiry on Flange Neck Thickness Adjustment During Hydrotest

    I have concerns regarding the estimation of nozzle and flange thickness under hydrotest conditions. A 30" flange with a Sch. 10S (7.92 mm) wall thickness was flagged because the nozzle assembly failed under hydrostatic test stresses. To mitigate this issue, I increased the nozzle neck thickness...
  2. Amr Shams

    Check saddle plate stresses

    when I add the option to check saddle plate stress, Base plate thickness increases a lot. can anyone explain the effect of checking saddle plate stress and whether it is mandatory or optional?
  3. Amr Shams

    Considering Corrosion Allowance in flange thickness

    A closed drain drum having a 2" nozzle with blind flange RF. Should I use the UG-34 calculations and include the corrosion allowance of the vessel to the flange thickness? or use the typical standard blind flange with a suitable rating without considering corrosion allowance? we already...
  4. Amr Shams

    Flange Derating

    Can anyone explain how the nozzle projection affects the flange rating while applying external loads.
  5. Amr Shams

    SA-182 F60 WNRF FLANGE IMPACT TEST

    In compress, After choosing class 150 , compress send the message attached , IMPACT TEST IS MANDATORY AS PER UHA (d)3. but when I change the class to 300 impact test is not required. I have the same message when I add external loads and increase nozzle projection. Can Anyone explain why? nozzle...
  6. Amr Shams

    Lethal Service / ASME Sec VIII Div 1

    How can you differentiate between an Sour Service with Lethal Service? All Lethal Service requires PWHT and 100% RT for butt welds for Pressure Parts. Do all Sour Service are Lethal in Nature? If not what is the requirements of sour services(non lethal) according to ASME VIII-Div1.
  7. Amr Shams

    Opening in standard blind flanges

    the fabrication period is too short.So we need to use a blind flange instead of UG-34 cover for quick supply.but we had a doubt that the blind flange can't has opening for nozzles because it doesn't meet the requirements of table 6 in B16.5 . I already used a UG-34 cover in design which worked...
  8. Amr Shams

    UW-21 minimum requirement for External weld for SO Flange

    When we ask the software company about the 9.02mm min.thickness. They told us that they add corrosion allowance after taking the lesser of (1.4x tn & hub thickness)!.this issue happens only when adding slip on flange to any pipe size with sch.160. If we use sch.80 or 40 it will has no deficiency
  9. Amr Shams

    Opening in standard blind flanges

    the opening in the blind flange is for nozzles center and off center. not tapered hole as table 6 recommends. so if the opening is for nozzles i can't replace the UG-34 cover in design with blind flange in fabrication process?
  10. Amr Shams

    UW-21 minimum requirement for External weld for SO Flange

    In compress, Using slip on flange in 2" pipe sch.160 will lead to a deficiency in external fillet weld. " UW-21: External fillet leg minimum (9.02 mm) is greater than the flange hub thickness (7.87 mm) " this message is shown during code calculation. but in UW-21 external fillet " X min = the...
  11. Amr Shams

    NOZZLE WELDED TO BLIND FLANGE

    Since compress does not allow attaching any nozzles (center or off center) to ASME B16.5 blind flange. Can I do the calculation with UG-34 cover to easily attach nozzles and in drawings replace it with Standard blind flange?
  12. Amr Shams

    Opening in standard blind flanges

    I am designing a pressure vessel using compress software .the PV is 24" OD and has a bolted cover. we want to use standard slip on flange & blind flange but we need to make an opening in the blind and we can't do it in compress. 1) can we use a UG-34 cover with the same dimensions of standard...