Good morning,
I am working on a new building that is right up against an existing building, where there are passages between the new and existing buildings. Neither the new or existing buildings has a basement, they are both founded at grade. At upper levels, I have expansion joints to separate...
Good Afternoon,
I am working on a model and comparing my hand check of the structure mass to the value calculated by Etabs. I notice that my hand calculation of 1.0SW + 0.8SDL matches with the numbers I get from etabs if I create a load combination 1.0SW + 0.8SDL, but it does not match the...
Good Morning,
I am determining the snow drift load on a low roof, which is adjacent to a high roof.
I know that the leeward case is covered by snow load case I for lower level roofs (4.1.6.5), and the windward case is covered by Case II.
Out of interest, I wanted to see how the load would...
Good Morning,
I am trying to wrap my head around pre-tensioned anchor rods; I have read a number of other threads and am still not quite there.
If I have an anchor rod pretensioned to 1500kN, and this is anchored into a concrete pier, does this add a 1500kN compression force to the concrete...
Hi,
I am coming onto a project with vertical post-tensioning designed as bonded post-tensioning, with grouted encasement.
The tendons have been installed and stressed, but there has been a delay of several months, and the ducts have still not been grouted.
They have been protected from...
Hi!
I am designing a roof with an RTU screen at a mechanical area.
I am wondering if there is a clause in the NBCC (or ASCE) that tells me how much clearance i need between the bottom of my screen and my roof to ensure that snow drift will not occur at the screen? Is it as simple as calculating...
Good Morning,
I am doing an analysis of an existing slab, and I'm interested in finding out how much rotation I would get at a point if I create a free edge (unrestrained from rotation)
Does anybody know how i can determine the slab rotation at an edge in SAFE?
Thanks so much!
Good Morning,
I have always used a trapezoidal / triangular soil bearing distribution when checking the maximum bearing on a gravity footing with eccentric loading.
I have been told by others at my office that I can use a rectangular distribution instead, with the average bearing pressure...
Good Afternoon,
I am designing several squat concrete shear walls with door / window openings. I haven't done this before and am wondering if anyone might be able to recommend any useful references or examples that they know of?
Thank you so much in advance!!!
Good morning,
I have received a contractor request to cut a new opening ~900mm x 900mm in an existing deep reinforced concrete beam (this is a perimeter wall and supports some vertical gravity loads, but does not retain soil. It spans between pilasters / pile caps).
Based on the same ideas for...
Hi,
A contractor has asked to replace beam stirrups at several locations with hairpins (135deg hook each end).
I don't love this idea, but can't seem to find any reason to say no.
I am wondering if there is any reason or code clause that would go against this change?
Thanks!
Good morning,
I am working on a post tensioned concrete slab, and have an opening cutting off my core wall from the slab.
Usually I would run tendons through the core wall, ensuring that they can exit the other side. From my understanding, this is to meet integrity reinforcing requirements...
Good Afternoon,
I am working with the farm building code and am having some difficulty with how it is laid out. There is a clause (cl. 2.2.1.11) that relates to tower silos, and another (2.2.1.14) that relates to storage for dry grains. If I have a tower silo for storage of dry grains, which...
Hi!
I have an embed plate with an infinite wall on all sides that is taking only shear. My shear force is pretty high (this is a girder framing into the end of a wall), and so I am thinking to design an embed plate with 20M rebar welded to lap with continuous 20M bars in the wall.
To check this...
Good Afternoon,
I've received a contractor request to switch to spiral ties in CFA piles, but looking at the Canadian code there is a minimum spiral tie pitch of 75mm. Has anyone done this before? This seems impractical and difficult to do, but I wonder if I am overlooking a clause that may...
Good Afternoon,
I am trying to model a floor in SAP to determine its frequency. So far I've done the following:
1. Modelled all the beams
2. Determined the I_cr.dynamic for the deck + topping (in steel units - i.e. concrete I is transformed based on the modulus of elasticity) - I got this from...
Good Afternoon,
I am working on a project with many transfer beams framing into the perimeter retaining walls.
I have checked the walls for bearing and also using the emperical wall formulas, and they work, but I wanted to do another check, considering each wall segment as an unconfined...