Hi,
Ya, it is quite confirmed that we are using ejector for the dosing system. The material would be SS316 or SS304, is erosion is still matters with this MOC?
Temperature of cPVC piping system for 98% concentration will be 27-31 degree celsius (at normal temperature in Malaysia)
Temperature of diluted acid estimated around 40 degree celsius.
We are looking at the enthalphy of dilution for the Sulphuric acid at the molar concentration to get the...
Dear Sir,
I see. 5% will be the concentration drops into the ejector. At the ejector outlet, it will be further mixed with the motive water (10 times more) based on the ejector water requirement.
Hi everyone,
Currently I am designing for a Sulphuric acid dosing system for a water treatment plant. It involves bulk storage at 98% concentration sulphuric acid and dosing at +/- 3% concentration sulphuric acid. The process involve inline dilution.
1) Chemical Storage System
I read from...
Hi, I am currently designing an ejector system for dosing of lime slurry to water treatment process. The purpose is for pH adjustment. I faced a problem in identifying the head loss in the hose because I couldn't get a specific value for the lime slurry viscosity. The lime slurry is prepared at...