  1. ThaiVu

    AWS D1.1 - FILLET WELD BREAK TEST

    Dear DekDee and gtaw, Thank you both of you for your response! Thai
  2. ThaiVu

    AWS D1.1 - FILLET WELD BREAK TEST

    Dear gtaw, Thank you for your comments. For the lack of fusion, I am clear. But I am confused about the inclusion or porosity which occurred at the root of weld (not root of joint). Actually, I had some test pieces of Fillet Weld Break Test showing porosity larger than 2.5 mm in the greatest...
  3. ThaiVu

    AWS D1.1 - FILLET WELD BREAK TEST

    Hi DekDee, I appreciate your help. But what is the exposed broken exactly? Does it begin at the root of joint or the root of weld? "Any inclusion or porosity larger than 3/32 in [2.5 mm] in greatest dimension in the exposed broken weld - fail" - I think you meant that it starts from the root of...
  4. ThaiVu

    AWS D1.1 - FILLET WELD BREAK TEST

    Hi Engineers/Experts I am a technician in the field of material testing. I had a small discussion of Fillet Weld Break Test with my colleagues. According to 6.23.4. - Acceptance Criteria for Fillet Weld Break Test, "The fillet weld, if fractured, has a fracture surface showing complete fusion...