Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. RickSewerPipe

    Sanitary sewer pipe thru box culvert?

    ....... The other requirement was that the pipe be of hard impact duty ...... so if lets say a backhoe drives thru the stream for example, it cant crush the pipe. Its my contention is that in lieu of this, the 2ft thick reinforced concrete box culvert itself affords an encapsulated protective...
  2. RickSewerPipe

    Sanitary sewer pipe thru box culvert?

    I put in a box culvert many years ago to cross a stream to reach an isolated residential land plot. The bottom floor of the culvert was left as bare concrete (I took this project on as I have never did one before! : ) The culvert was 30 tons! The crane was massive and cost $2,500.00 for the 30...
  3. RickSewerPipe

    Sanitary sewer pipe thru box culvert?

    This township's codes requires the sewer main to be embedded 2 feet under the stream bed or in hard rock areas, 1 foot. I could meet this criteria easily within the emulated bed stream going thru the culvert.
  4. RickSewerPipe

    Sanitary sewer pipe thru box culvert?

    @bimr Hi bimr! : ) ........ thanks for your input! I hear ya in all that your saying ........ but you really have to see the aerial topography of the areas in question here. Basically, its a small motel located in a rural area up on a hillside with a 4 lane major highway in front...
  5. RickSewerPipe

    Sanitary sewer pipe thru box culvert?

    @bimr: What are you running, a gravity sewer or a force main? Forced lateral (pumped) ...... with siphonic drain function as a back-up. This 2" lateral is 450ft long!! The vertical height differential from starting elevation to end discharge into the township's gravity sanitary sewer is 40ft...
  6. RickSewerPipe

    Sanitary sewer pipe thru box culvert?

    @FEL3 Thanks for your response! The township sewer engineer is agreeable to this, but said I would have to get PA STATE approval and permit if they allowed this. ...... and other authorities may also want permissions as well (EPA, etc)
  7. RickSewerPipe

    Sanitary sewer pipe thru box culvert?

    Hello Eng-Tips.com community! :) I need to cross-under a four lane state highway to get to the township's gravity sewer main on the other side. In lieu of pneumatic tunnel boring (expensive) the ideal point of cross-under is at an existing state owned box culvert with a low flow stream...