Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. M

    Joint efficiency - UG-27 ASME BPVC

    Thank you ! It has been only a year for me, so I don't know his name and often have questions. So, according to you, the coefficient 2 shouldn't appear in these formulas ? Then the value of E to consider for the calculation of the thickness of the shell would be 0.7 ? Thank you once again and...
  2. M

    Joint efficiency - UG-27 ASME BPVC

    Good morning and first of all, thanks for your answer ! I'm reading this on the webpage i shared, it says "Circumferential joints – Table UW-12 column (c) = 0.70 x 2 = 1.4" So yes, there is probably a link with the coefficient 2 you mentionned between loads in hoop and axial directions of a...
  3. M

    Joint efficiency - UG-27 ASME BPVC

    Hi everyone! This is my first thread here, and I’m sure it won’t be the last! I’ve searched the forum for an answer, but I haven’t found one—so I’m relying on your expertise. I’m designing a vessel according to ASME BPVC Section VIII, Division 1 (2023), and I’m calculating the pipe per...