    AWS D1.1 new Clause 9

    I contacted AWS and they admitted that the word PLATE had been mistakenly omitted from TABLE 9.10. AWS will publish an errata addressing this omission soon. Thanks
  2. WP23

    AWS D1.1 new Clause 9

    Thank you
  3. WP23

    AWS D1.1 new Clause 9

    AWS D1.1 2015 new Clause 9. Previous versions of D1.1 Table 4.2 (2. Test on Pipe or Tubing). Previous wording was "Nominal Plate, Pipe or Tube Wall Thickness Qualified, in". The new 2015 version reads "Nominal Pipe or Tube Wall Thickness Qualified, in". The word Plate is missing, is this an...