    Rupture Disc Nozzle Location

    Liquid drain out was my main concern with respect to safety especially due to potential pressure built-up on the shell side, but also due to high velocity liquids in the flare system. The case is that a vendor has supplied this to us on a 250 barg compressor CM after cooler and I just wanted to...
  2. Stampe

    Rupture Disc Nozzle Location

    Usually the nozzle for a rupture disc on a water cooled high pressure gas T&S heat exchanger is located at the top of the shell. Is it acceptable to locate the nozzle at the bottom of the shell from a safety point of view? Thanks