Dear all,
I don't know if this is the right module of the Forum for asking you what I need. I am trying to search something useful for studying APIs manufacturing production (synthesis process and fermentation). Please, could I kindly ask you to help me in this reasearch or advice any...
Dear all,
sorry for bothering you again. Please, could you help me about the value of clean utilities velocity in Pharmaceutical Industries, according to the normatives. Sorry, I don't know how specifical normative reports this value. It is necessary to ensure turbolent regime in order to avoid...
Dear all,
please I ask your help for a valuation of PED for piping. Could you please write me when a piping is classified as PED? And could you give me the definition of "full vacuum" for a piping? Sorry for the commonplace questions and thanks for all your support.
Luisa
At the end, I have found that 1/N <= 0,7^2 * Dp^2 *pi^2 / (4*Ao).
Hope this is the right way to solve.
Plaese, give me your feedback, if you want.
Thank for all,
Luisa
Dear Pierre,
if I consider the following formulas:
- DeltaPp=pressure drop in pipe caused by friction=alfa*rho*Vp^2/2, see formula (1), and I explicit Vp as a function of the volumetric flow rate Qp, what I obtain is = alfa*rho*(Qp/Ap)^2/2, where Qp=know value (25Nm3/h to convert in Nm3/s)...
Dear Pierre,
thank you for the document you have sent to me. It is very insteresting. The only formula I have to use is (5), but I have n°2 unknown values (the diameter of the single hole, D0, and the number of the holes, N). It is necessary to fix at least one of the unknown values, right...
Dear all,
in detail,
- Our perforated-pipe distributor, or sparger, must have pharmaceutical charateristics. So it must be in AISI 316L stainless steel, not in carbon steel.
- The depth must be defined. Regarding this argument, please what are the parameters to be considered for having the...
Please, try now and refer to N2 lines.
Luisahttps://files.engineering.com/getfile.aspx?folder=5e4aaac2-c6ab-4325-8730-f430ffba2f8a&file=1K3021010-SM-0001_01_Preparation_Ampoules_Line_2_Fase_di_riscaldamento_page-0001.jpg
Dear all,
I ask you pardon for my inadequate information. This is my fist approch to a pure engineering design. For this reason, I ask you a little piece of patience, if I am not very clear during my explanation. Please, I try to write you all the details I have. You can find a P&ID detail in...
Dear pierreick,
thanks for the brochure. Anyway, I would need a procedure or a formula for dimensioning this kind of sparger.
We have just seen on the vendor website. Something useful is written, but at the end it is necessary to decide the sparger configuration according to Mott sparger types...
Dear Latexman,
clean service. Nitrogen is used to deoxygenate the aqueous solution during its preparation. I have found in Internet this procedure https://www.cheresources.com/invision/blog/4/entry-353-perforated-pipe-distributor-sizing-calculations/ , but dimensionally I think something is...
Hi everyone.
please, I need some help for a project I am working on. My collegues and I are designing a pharmaceutical vessel for the preparation of injectable solutions. Now we need to design a gas sparger (in particular, Nitrogen sparger). The only data we have are the gas flow rate (25...