  1. ekuegler

    Phase-Earth voltage in an ungrounded system during fault

    Can anyone confirm what readings I should be obtaining when testing for voltage phase-earth on a system which is ungrounded and has a ground fault. 440v phase-phase in normal operation. Would a voltage of 440v to earth indicate a ground fault or would you expect zero volts in the grounded phase...
  2. ekuegler

    Synchronising Emergency Generator 1.8MW

    Hi, Wondering if anyone can assist me. We have a 1.8MW Emergency generator that we usually carryout 3 weekly load runs on, normal practice is to auto synch with main generation. My question is we have a power management system controlling the main generators to a pre set base load 95% of...
  3. ekuegler

    2.24kW Pedestal Grinder - protection

    Wondering if anyone can help me out, we have a 2.24kW pedestal grinder supplied at 440/60/3 - 0.85p.f - would using a 2.5mm2 SWA cable to supply be adequete with a 10A MCB protecting the cable. calculated the 3 phase current to be 3.5A - anyone suggest/comment on the cable/MCB used. Are these...
  4. ekuegler

    Testing a brushless generator

    Can anyone describe how to test a brushless generator. Looking to test stator - no issues, PMG stator no issues, main excitor stator no issues. Will test diodes - no issues. Just need to clarify the exact correct way to test the rotor. Would disconnecting the diodes & dc cables from the diode...
  5. ekuegler

    VFD - abnormal readings!!!!!

    Wondering if anyone can help here. We have an ABB ACV700 VFD, supplied by a 690vdc bus, 690vac to a step up transformer to 2600vac supplying a downhole ESP motor. Drive currently operating/running - however pump discharging very little....? Hertz = 3.5-4Hz, ref = -25.7 and current 413A. This is...
  6. ekuegler

    IR TESTING DELTA CONNECTED MOTOR

    Hi all, Can someone please state the correct method to adopt in testing a delta connected 3 phase motors insulation resistance, & how it differs from testing a star connected 3 phase motor. We are having a dispute on the matter & an un-baised opinion would settle the argument. Many thanks. EK
  7. ekuegler

    Convection oven operation/philosophy

    Can anyone explain to working of an industrial convection oven/steamer. What possible causes attribute to a safety thermal switch operating. Product Elamo B10-11, could a defective water inlet solenoid cause the thermal switch to operate due to stagnant heat not being circulated hence heat...
  8. ekuegler

    Live working LV - Required controls to satisfy EAWR 1989 Reg 14

    Can anyone outline what is required in terms of controls to conform to the EAWR 1989 Reg 14 - live work on LV system/in the proximity of live conductors. Your help would be appreciated
  9. ekuegler

    Blocking Magnet purpose in HV SF6 circuit breaker

    Can anyone explain the purpose of a blocking magnet within a 11kV ABB SF6 circuit breaker, what is it's function. Circuit breaker is motor charged with 1x shunt trip, 1x closing coil and a blocking magnet. Thanks for your help
  10. ekuegler

    Replacing dual UPS maintenance bypass switch.

    Hi all, Looking into feasibility of replacing a dual UPS (Chloride) maintenance bypass switch. Switch configured so that it has both UPS's terminating into it, live at all times via one UPS or the other. It is a F&G UPS, plant will be shutdown on isolation of power to catastrophic level. Is...
  11. ekuegler

    ABB Sace F5 ACB 440v

    Has anyone got an ops manual for the above ACB. or can anyone give guidance on it's operation.
  12. ekuegler

    Method of proving a HV system/drive dead

    Hi, Previously touched in another thread, can anyone outline the correct procedure/step by step method to adopt in proving a HV 3 phase, 11kV system dead given the system is an unearthed type...? Also can you provide opinions for the above but LV system relative. I would appreciate your input...
  13. ekuegler

    Alternator Issues post bad weather/unit shutdown

    Hi all, Can you explain the effects of a large imbalance between phases R-Y, R-B = 0.38 milli ohm Y-B = 4 ohm when a generator is ductored, IR/PI good. Star bar disconnected, IR between phases good. Line to line ductor all 3 phases identical. Only when star bar connected is there an issue...
  14. ekuegler

    Tertiary transformers Dd0y11

    We have a tertiary transformer feeding a DC 690v bus (part of a multi VFD) dist system, DC link section. Can someone explain why this type of Tx was used for this application, assume cost related...! and also explain how the secondaries that feed the same bus differ in configuration one being...
  15. ekuegler

    IT unearthed marine (offshore) elect systems

    Hi all, Happy New Year......! Would appreciate your advice. Can someone please indicate the correct procedure to adopt in proving an unearthed IT electrical systems dead. (Offshore Oil/Gas Platform) With no theoretical earth I would assume that to test for no volts/a dead system you would...