  1. eng003

    Bottom bearing wood floor truss, 2nd floor wall tie down

    I have a two story structure first floor cmu 2nd story wood stud frame located in high wind area. Need to tie down 2nd floor studs to bond beam below 2nd floor wood trusses. Trusses bear on 2x plate with anchor bolts into masonry bond beam. Would like to use Simpson coil straps or simliar...
  2. eng003

    column - vehicle impact protection

    I have an isolated column that will be in close proximity to where cars will come in and out. Structure is a larger garage/barn accessory to residential. Apart from it being a good idea does any know of a code requirement i.e. ibc/irc for protecting the column from the vehicles? Also, what would...
  3. eng003

    large span conv. framed hip roof ceiling joists

    Looking at a 34' span (short width) 2nd story renovation in which contractor wants to conventionally frame a hip roof. 4:12 pitch no snow but high wind. Maze of existing bearing wall lines below to use but unfortunately mainly parrallel to the potential ceiling joists/rafter ties. Thinking of...
  4. eng003

    live load - alf living room

    I have an existing assisted living facility renovation where flat wood roof trusses designed for 40 psf live load will be use for the floor system for a second story addition. Part of the addition will be bedrooms and other part common areas (living room) although not specifically addressed in...
  5. eng003

    masonry/wood structure shearwall combination & code requirements?

    This may be difficult to describe without a sketch but I do not have one handy so here it goes: I have an existing 2 story old wood framed structure to which a one story cmu masonry addition was added. On about 50% of one of the addition wall was the original wood frame 1st story wall. Client...
  6. eng003

    lumber roof sheathing

    Looking for general formation on 1x, 2x, & 3x lumber roof sheathing. Pro's con's, design considerations, etc. -I note awc has a technical pub on 2x & 3x but what about 1x what design values do you use for that? -the tech pub shows some installation patterns where they appear to stagger with ends...
  7. eng003

    Load Path to Roof Diaphragm w/ Overhang Trusses - See Detail

    Interested in how others typically transfer load from exterior wall to roof diaphragm when dealing with trusses overhanging a porch. Please see attached detail, initial plan is to use the jack trusses as drag struts and sheath the porch ceiling with 3/8" plywood. Even with the high wind it is...
  8. eng003

    Detail Critique - Wood/Masonry Wall Section w/ Kicker Brace

    Looking for a critque of the attached detail. There few things I am not thrilled about but specifically the kicker brace. I do not like the idea of making them thread the brace through the truss...expecting interference and trouble placing. Considered taking wall studs down to the plate on the...
  9. eng003

    flood vent requirements

    If one can demonstrate a wall is capable of withstanding load from hydrostatic flood pressure do building codes and/or asce 24 still require flood venting?
  10. eng003

    split face cmu lintel options

    With an exposed split face CMU construction what are the options & pro/cons for lintels. Are there any masons who still form up U block and pour? How abour power steel products??
  11. eng003

    Typical Garage Doors - Wind Borne Debris & Flood Loads?

    I have a project located in a wind borne debris area and in a flood zone. The structure has several garage overhead door openings. Are there garage doors rated for for hydrostatic loadings?? Are there garage doors rated for wind borne debris?? Are these strctures typically designed as partially...
  12. eng003

    real world examples of shearwall or diaphragm failures for wind

    I am in the midst of a detailed design spredsheet for 1-2 story structures for high wind areas and am need of some inspiration for actual failures....apart from having no uplift tiedowns at all and no gable end bracing...I see so many old structures still standing and can't stop thinking of all...
  13. eng003

    Ring Shank Nail Withdrawl Loads Roof Sheathing & Diaphragm - NDS verse FBC

    The florida residential building code (and maybe the IRC?) presriptively requires 8d ring shank nails for roof sheathing attachment I have the following questions regarding their use: 1. What are their withdrawl loads? NDS doesn't seem to address unless it is appropriate to use the threaded nail...
  14. eng003

    ASCE 7 MWFRS Wind Load Case 3

    I am working on a design spreadsheet for lateral wind design of one and two story structures. The structures will all all have wood roof and/or floor diaphragms (flexible). Walls will either be frame or masonry. For these type of strucutres ASCE 7 notes you only have to evaluate CASE 1 & 3 of...
  15. eng003

    wood floor trusses to exterior bearing wall

    Looking at 2 story 8" cmu structure to have wood floor & roof trusses. Floor trusses likely be 24"+/- depth. Interested in opinions/reccomendations on detailing floor truss connection to wall i.e. top bearing, bottom bearing, hanger, ledger, pocket, moisture break, cmu bond beam verse cip...
  16. eng003

    Typical ICF vertical reinf. spacing verse ACI-318

    I see typical vertical reinforcement spacing in ICF at 48" +/- o.c. depending on the loads. You will arrive at similiar spacings if you follow the prescriptive pca-100 design guide. I am using the AMVIC ICF system software and it is noting my 48" spacing is violation fo ACI 318-08 14.3.5 and I...
  17. eng003

    ICF construction on CMU stemwall

    Contractor wants to do ICF construction on solid grouted reinforced CMU stemwall with slab on grade. This is a one story story residential structure in high wind. I have have heard another engineer have issue with this approach, as depending on the nature of the icf system you maybe stacking a...
  18. eng003

    CMU wall cracking photos

    Looking for opinions on cause of minor exterior wall cmu cracking see attached photo. Cracking starts small at ground and start steps up as it widens to left bottom corner of window opening, second crack starts small from bottom right of window opening stair steps downward widening to corner of...
  19. eng003

    evaluation of potential for foundation settlement

    For a non-geotech, what are the general methods & procedures & tests used by geotechs for analyzing potential for foundation settlement of both a new site and in the case of an existing structure the potential for further settlement? I assume geotech evaluate several things i.e. type of soils...
  20. eng003

    multi-ply continous wood beam fastening

    For a typical continous multiply 2x wood beam I often see detailed lag or through bolts staggered. The required fastening to develope the plys on either side of splices at zero moment is not somehting I would typically try to quantify exactly ( I would opt to over do it) but I am questioning...