  1. TekEngr

    Parking Shed Drifting Limit??

    someone can guide me with code reference, what should be drifting limit for this kind of open parking shed ?? roof cladding is steel sheet.
  2. TekEngr

    ASCE 7-10 Minimum Wind Load (MWFRS Envolpe Method).

    As per ASCE 7-10 , 28.4.4 minimum wind load should not be less then 16 psf for walls , so what is this mean ? I am using MWFRS envolpe method and my structure is closed structure .One of my friend told me that if sum of my windward and leeward value comes less than 16 psf than i have to apply 16...
  3. TekEngr

    Beauty Salon Floor Live Load?

    I am designing a 2 storey small light gauge steel beauty salon (total area each floor 64m2), but i am confused in live load what should i consider live load for first floor. First floor containing makeup area zone , facial persnol care, manicure area etc.
  4. TekEngr

    As Per IBC Vertical Deflection Limit L/120 Is It Reasonable ???

    i am designing a steel portal frame for industrial shed , which is 36 meter in clear span , as per IBC code allowable vertical roof deflection limit is L/120 (not supporting ceiling ) against Dead + Live Load and L/180 against live load which means allowable deflection for my portal frame is 300...
  5. TekEngr

    Solar Panels effect on PEB Building's Roof.

    I am desiging a pre engineered building which is 44m in width , 120m in length and 8.5m eave height (Metal roof slope is 4 degree). I made the calculations for wind forces by using the code ASCE 7-05 in result all the wind load forces are upward (suction) on roof steel rafters , but now client...
  6. TekEngr

    Gym on First Floor.

    Client wants the gym on first floor of 2 storey steel building (semi equipped gym). Gym size is 12mx18m. Main frame structure is consist of hot rolled columns and beams and peimary member of floor is cold form steel joist (back to back Cee sections) @ spacing of 300mm center to center and as a...
  7. TekEngr

    Boundary wall post deflection limit?

    i am using H shape steel column as post of boundary wall and using inside post to post light weight concrete planks. Any one can tell me allowable deflection limit of H shape steel post against wind force??, and any code reffrence??
  8. TekEngr

    Dry wall DB (Decible) value?

    Any one can tell me what DB level we can achive if we use 90mm C section steel wall with both side single layer of 16mm gypsum board. Any code reffrence ?
  9. TekEngr

    Factored or service load B.C value??

    I am designing an isolated footing of a steel column on SAFE , the bearing pressure value is 67kpa and 90 kpa on service load and factored load respectively with 5mm and 8mm settelment similarly. And soil investigation report says that the net allowable bearing capacity is 70 kpa based on...
  10. TekEngr

    Grade Beam With Isolated Footing

    I am designing a grade beam which is connected with the isolated footing pedestal both side, furthermore the grade beam is carrying the self-weight of block wall so I have few confusion as mentioned below can someone please suggest in this regards. 1: grade beam is carrying the self-weight of...
  11. TekEngr

    Aerated Concrete Infill in LGS walls??

    i am designing a single storey light gauge steel structure with aerated concrete infill (650kg/m3) in walls and both sides of the wall is cement board permanent shuttering, so i have one doubt that if the structure is single storey do i need to take self weight of aerated concrete while...
  12. TekEngr

    Beam To Beam Moment Connection ??

    I have a 1.5m overhang with concrete and decking sheet. Main beams and secondary are on same level so moment connection needs to made between the main and secondary beam (Cantilever Structure.jpg). I have two options for connection. 1. Fin plate in between and flat plate on top and bottom (Con...
  13. TekEngr

    Slab On Grade Foundation For G+3 Structure??

    I am designing a slab on grade foundation for G+3 hospital building, loads are coming on slab foundation through LGS walls and steel columns (UDL loads and Point Loads). Plot is 1.5m deep from adjacent road level so we have plan to fill that plot with special granular material up to road level...
  14. TekEngr

    20m Span Floor I Beam VS Truss Beam

    I am designing a double story amphitheater and clear span of this structure is 20m ,so i am stuck in floor beam design , either it should be a simple I beam(Standard Sections) or i should go with hot rolled truss beam so any one can suggest for this type of clear span (20m) which option will be...
  15. TekEngr

    Slab on Grade With Trench???

    Hello Everyone!! I am designing a slab on grade for warehouse (sizes 10mx20mx6m) , which carries the load from steel column at the edge of slab , but the issue is that , a 250mm deep trench is running for electrical cabling along the steel column throughout in 250mm thick RCC slab so below is my...
  16. TekEngr

    Soil Bearing Capacity from SPT or CPT value???

    Any one can tell me how i can calculate soil bearing capacity at 2m level from below provided data however in soil test report soil bearing capacity is recommended 0.75kg/cm^2 at 1m depth for shallow foundations but i want to construct my footing below the underground water table level at 2m...
  17. TekEngr

    Soil Bearing Capcity From Cone Penetration Test Data???

    Any one can tell me how i can calculate soil bearing capacity at 2m level from below provided data however in soil test report soil bearing capacity is recommended 0.75kg/cm^2 at 1m depth for shallow foundations but i want to construct my footing below the underground water table level at 2m...
  18. TekEngr

    Shallow Foundation & Underground Water Table???

    I am designing a shallow foundation for a G+3 hospital structures, according to soil investigation report the bearing capacity of soil at depth of 1m is 0.75 kg/cm2 (medium stiff clay type) and at depth of 2m the bearing capacity is 1.55 kg/cm2 (medium dense soil)but the problem is that the...
  19. TekEngr

    Increment of Soil Bearing Capacity???

    Any one can tell me any thumb rule to find the approximate increment value in bearing capacity of soil (for initial design) after proper compaction and adding the selected granular material??? For example existing soil bearing capacity is 50 KN/m2 if we do compaction in proper way and add 30...
  20. TekEngr

    Increment in Soil Bearing Capacity???

    Any one can tell me any thumb rule to find the aproximate increment value in bearing capacity of soil (for inetial design) after proper compaction and adding the slected granular material???   For example existing soil bearing capacity is 50 KN/m2 if we do compaction in proper way  and add 30...