Currently purchasing a replacement 10" angle motor operated globe valve (see attached file) with the following parameters:
- End use is a Vacuum Breaker valve off of a steam condenser.
- Designed for operation in a full vacuum service (below the disc). The design pressure is 29.5 in. HG. VAC...