Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations cowski on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: faisal45
  • Content: Threads
  • Order by date
  1. faisal45

    Dynamic Analysis According to ACI & UBC

    When a concrete building should be considered for dynamic analysis? what will be the specification according to ACI & UBC code.
  2. faisal45

    Pile Construction

    Dear All, i designed a pile which dia is 20", length = 50'-0". but the problem is when site engineer is doing construction caving occurs. he told me caving length is almost 5'-0". they use 11 bags cement instead of 18.5 bags. what should i do now? cancel it and design another pile?? Faisal
  3. faisal45

    Pile Construction

    What will happen if pile reinforcement comes to soil contact? What will be the precaution of caving?
  4. faisal45

    Structural question on wall design

    Dear All, i got from a manual that if Pu/Po < 0.35f'c x Ag then wall detailing is necessary. but if Pu/Po > 0.35f'c x Ag then wall can be detailed as column. i checked this equation in UBC Code and ACI code but did not get any information about this equation. can i follow this equation for...
  5. faisal45

    Analysis problem on ETABS

    Dear All, i use ETABS to do analysis of RCC building. sometimes i get that rebar percentage of column bottom portion is lower than the top portion of that column. for example today i have got at bottom portion (Ground floor) rebar percentage is 1.2% but in the top portion (10th floor) rebar...
  6. faisal45

    Structural question on dynamic load analysis

    Dear All, Do you think flat plate design is alright for dynamic load analysis? explain your thoughts. Thank you. Regards Engr. Faisal
  7. faisal45

    Swimming Pool

    Dear All, i have to design a swimming pool on the top floor of a residential building. bottom slab of pool is 4'-0" above the floor slab. pool size is 33'-8" x 12'-1" having variable depth 3'-0" to 6'-0". i want to know that what will the pool bottom slab thickness and what will be the...
  8. faisal45

    Structural question

    Dear All, is there any problem of designing two way slab having thickness 8 inches though other adjacent slab thickness are 6" and 5"? what kind of consideration i will take while performing the slab design? Thank you. Regards Engr. Faisal
  9. faisal45

    Structural question

    Dear all, i just want to know is it possible to perform a design two way slab using flat plate which has two span only.i attached a file i can provide beam only to the stair portion but i cannot provide beam in other portion because of architectural requirements. please consider RCC Slab. Thank...

Part and Inventory Search