Hi folks,
We're working on the design of a system that uses four hydraulic cylinders for lifting a payload. The cylinders stand on the ground and the payload is not otherwise guided. Because of the distance between the cylinders, they're not hydraulicaly coupled - each is driven by its own...
I'm sizing a hydraulic pump and DC motor and I'm surprised about the electrical power in v's hydraulic power out I get in my calculation. I'd apperciate if someone could confirm if this is right.
I have been given motor data at 24V DC:
4950 rpm using 6 Amps when 0 Nm torque
3150 rpm using 90...
Hi guys - I'm looking for some comments / suggestions.