  1. Tony1t

    Table PW-39-3 circumferential butt welds under Section I

    Do the postweld heat treatment exemptions for circumferential butt welds noted in Table PW-39-3 apply to the welds illustrated by Figure PW-16.1, illustration (a)? Thank you in advance
  2. Tony1t

    Select appropriate pipe OD for calculating Fitting (B16.11-2011)

    Hi everyone, I was caculating a minimum wall thickness for half coupling fitting NPS 11/2, but B16.11-2011 said that "Within these limits, the minimum wall thickness for pipe to be used with a Table 7 Class designated fitting shall be computed based on appropriate size straight seamless pipe of...
  3. Tony1t

    Pipe Cap elliptical ratio

    I designed a vessel with B16.9 pipe cap as head. B16.9 said that the shape of these caps shall be ellipsoidal and shall conform to the requirements given in the ASME Boiler and Pressure Vessel Code. Which elliptical ratio should be indicate in MDR? thkx .
  4. Tony1t

    Current range value was specified in PQR when make tube to tubesheet qualification as per QW-288

    Hi everyone, A question was raised as current range value was specified in PQR when make tube to tubesheet qualification as per QW-288. When I reviewed WPS for tube to tubesheet at shop found that a curent range value(235~300 A) was specified in WPS, alike a current range value (260~275 A)...
  5. Tony1t

    Current range value was specified in PQR when make tube to tubesheet qualification as per QW-288

    Hi everyone, A question was raised as current range value was specified in PQR when make tube to tubesheet qualification as per QW-288. When I reviewed WPS for tube to tubesheet at shop found that a curent range value(235~300 A) was specified in WPS, alike a current range value (260~275 A)...
  6. Tony1t

    Impact tests required on austenitic ferritic duplex steel

    Are impact tests required on austenitic ferritic duplex steel,as attachment bracket plate of leg which essential to the structural integrity when weld to preesure part,when the MDMT is +32°F or colder, and the thickness limit of UHA-51(d)(3)(a) in Section VIII, Division 1 is exceeded? thks !
  7. Tony1t

    Material Identification Marking

    Hi Everyone, I have a lots of fittings SA-105,which with same heat number, same class and manufacturer, only different is size. where coded marking be use, UG-77(a) requires the transfer of "the original identification markings required in the specifications for the material,is it acceptable to...
  8. Tony1t

    ASME V Backscatter

    Hi Everyone, Is it mandatory to ASME V T-223 which place a lead letter "B" to back of film holder while performed an XRay? THKS!
  9. Tony1t

    Perform an Xray before PWHT

    Is it permit to perform an XRay examination on welds of vessel or boiler before PWHT? I do appreciated in advance.
  10. Tony1t

    ASME 2011A section II-D table 1A General Notes(e)

    Hi everyone, ASME 2011A section II-D table 1A, General Notes(e) said that Stress values for −30°C to 40°C are applicable for colder temperatures when the toughness requirements of Section III, VIII, or XII are met. If impact test is exempted per ucs-66,ASME SECTION VIII-1, is't need still to do...